Details

Analiza tlačnih izgub v prenosnikih toplote pasterizatorjev
ID Slak, Blaž (Author), ID Šajn, Viktor (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (14,30 MB)
MD5: C3B9ABE36F628F4D28F8C16A3345EA18
PID: 20.500.12556/rul/475bc4e8-2f47-4587-8284-27029d0ffa37

Abstract
Delo obravnava tlačne izgube v prenosnikih toplote pasterizatorjev mleka. Za meritve tlačnih izgub smo zasnovali merilno verigo in, pri različnih pretokih vode, izmerili izgube na več različnih prenosnikih toplote. Naredili smo odtis oblike prenosnika toplote in izračunali njegov hidravlični premer. S pomočjo Reynoldsovega števila smo določili tokovne režime. Izdelali smo empirični model za izračune tlačnih izgub za različne prenosnike toplote, s pomočjo katerega lahko izberemo primerno črpalko. Rezultate smo medsebojno primerjali in ovrednotili.

Language:Slovenian
Keywords:prenosnik toplote, merilna veriga, tlačne izgube, karakteristika sistema, hidravlični premer, izbira črpalke, empirični model, mehanika fluidov
Work type:Master's thesis/paper
Organization:FS - Faculty of Mechanical Engineering
Year:2017
PID:20.500.12556/RUL-92952 This link opens in a new window
Publication date in RUL:11.07.2017
Views:2563
Downloads:354
Metadata:XML DC-XML DC-RDF
:
SLAK, Blaž, 2017, Analiza tlačnih izgub v prenosnikih toplote pasterizatorjev [online]. Master’s thesis. [Accessed 5 June 2025]. Retrieved from: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=eng&id=92952
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Analysis of pressure loss in heat exchanger in pasteurizers
Abstract:
In the present thesis, analysis of pressure loss in heat exchangers in pasteurizers is presented. For measuring of the pressure losses, measurement system was conceived. Losses were measured on various heat exchangers at different water flow rates. Footprints of heat exchangers surfaces were made and hydraulic diameters were calculated. With calculated Reynolds numbers flow regimes were determined. Empirical model for the calculation of pressure losses was developed for easier selection of the suitable pump. Results were compared and evaluated.

Keywords:heat exchanger, measurement system, pressure loss, system curve, hydraulic diameter, pump selection, empirical model, fluid mechanics

Similar documents

Similar works from RUL:
  1. Etični vidiki zdravstvene nege pacientov v enoti intenzivne terapije
  2. Soočanje staršev prezgodaj rojenega otroka s stresno situacijo v enoti intenzivne nege in terapije novorojenčkov
  3. Bolečina pri otroku v enoti intenzivnega zdravljenja
  4. Znotrajbolnišnični transport kritično bolnega pacienta
  5. Dojenje prezgodaj rojenih otrok
Similar works from other Slovenian collections:
  1. Zanesljivost točkovnih sistemov za vrednotenje zahtevnosti zdravstvene nege v enoti intenzivne terapije
  2. Obvladovanje stresa medicinskih sester v zdravstveni negi v enoti intenzivne terapije
  3. Preprečevanje okužb osrednjih venskih katetrov v enoti intenzivne terapije operativnih strok Splošne bolnišnice Jesenice
  4. Pojav sindroma izgorelosti pri medicinskih sestrah v enotah intenzivne terapije
  5. Timsko delo kot dejavnik za zmanjševanje stresa pri zaposlenih v zdravstveni negi v enotah intenzivne terapije

Back