Abstract
V svoji diplomski nalogi sem poračunal nosilnosti vijačenih stikov IPE nosilcev s podaljšano čelno pločevino, z uporabo komponentne metode. Najprej sem na splošno predstavil katere kontrole je potrebno upoštevati pri dimenzioniranju tega spoj. Ugotovil sem, da je potrebnih 15 kontrol. Nato sem se osredotočil na svoj primer, in sicer na spoj prečka - preča. Nosilnost stika določim na podlagi 4 kontrol, in sicer kontroliram upogib čelne pločevine, natezno nosilnost vijakov, natezno in tlačno nosilnost stojine nosilca. V drugem delu diplome sem po korakih predstavil postopek računanja, ki mu bo sledil zgled z vsemi računi. Rezultate izračunanih spojev z različnimi nosilci, kvalitetami jekla in številom vijakov sem predstavil v tabelah nosilnosti v prilogi C.

Language:Slovenian
Keywords:gradbeništvo, diplomska naloga, UNI, gradbene konstrukcije, jeklene konstrukcije, dimenzioniranje spojev, nosilnost
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Place of publishing:Ljubljana
Publisher:[R. Morgan]
Year:2016
Number of pages:X, 40 str., 3 pril.
PID:20.500.12556/RUL-86488 This link opens in a new window
UDC:624.014.2:624.046.2(043.2)
COBISS.SI-ID:7848801 This link opens in a new window
Publication date in RUL:09.12.2016
Views:4183
Downloads:835
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Resistance tables of IPE beam-to-beam connections with extended end plate
Abstract:
In this thesis the resistance of bolted connections of IPE profiles with extended end plates were analysed by the component method. This thesis begins with the presentation of required design checks for the design of bolted column-to-beam connection. There are 15 checks for his kind of connection. The analysis of beam-to-beam connection is presented after that. There are only 4 design checks for determining the resistance of this kind of connection, namely the end plate in bending, the beam web in transverse tension, the beam flange in transverse compression. The second part of thesis represents the design procedure for the calculation of beam-to-beam connection with the example. The results of the analysed connections with different beam sizes, steel grades and number of bolts are represented in tables in Appendix C.

Keywords:civil engineering, steel structures, bolted joint, component method, design, designing joints