izpis_h1_title_alt

Nadzor ravnanja z balastno vodo - indikativne metode : diplomska naloga
ID Golja, Aja (Author), ID Žagar, Dušan (Mentor) More about this mentor... This link opens in a new window, ID David, Matej (Co-mentor)

.pdfPDF - Presentation file, Download (1,77 MB)
MD5: 840CF2E7C7A5E0572374EA6CE2DE7292
PID: 20.500.12556/rul/17382e03-9e14-446f-9f76-7c8e860d2a1f

Abstract
Ladja potrebuje balastno vodo za zagotovitev ustrezne stabilnosti in obremenitev ladijskega trupa pri tovornih operacijah in za varno plovbo, kadar ta ni polno naložena s tovorom. Balastna voda vsebuje usedline, organizme ter povzročitelje bolezni, ki se prenašajo z balastno vodo iz ene geografske lokacije na drugo. Ladje so tako eden glavnih prenašalcev vodnih organizmov in povzročiteljev bolezni po svetu. Pravilo D-2 mednarodne Konvencije za nadzor in ravnanje z ladijsko balastno vodo in usedlinami zahteva, da ladje izpustijo z balastno vodo manj kot predpisano število za preživetje sposobnih organizmov na določen volumen balastne vode, in sicer zaradi preprečevanja prenosa, širjenja ter vnosa škodljivih vodnih organizmov in povzročiteljev bolezni po svetu. Konvencija tudi predpisuje inšpekcijski pregled ladje za ugotavljanje skladnosti z zahtevami Konvencije. Pomorska inšpekcija vzorči balastne vode na ladji in izvaja hitre indikativne analize vzorcev balastne vode z indikativnimi inštrumenti ali opravi podrobno testiranje. Opisali smo možne metode reprezentativnega vzorčenja ladijske balastne vode in indikativne analize vzorcev z razpoložljivimi inštrumenti za nadzor skladnosti s Konvencijo. Namen naloge je bil oceniti uporabnost izbranega inštrumenta Walz Water PAM za indikativno analizo balastnih vod. Ocene inštrumenta Walz Water PAM smo primerjali z rezultati podrobne analize vzorca v laboratoriju in zaključili, da gre za instrument primeren za indikativne analize pri nadzoru skladnosti balastne vode s Konvencijo.

Language:Slovenian
Keywords:gradbeništvo, diplomska naloga, UNI, VKI, balastna voda, vzorčenje, nadzor, skladnost, konvencija, indikativne metode
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Place of publishing:Ljubljana
Publisher:[A. Golja]
Year:2016
Number of pages:XIV, 43 str.
PID:20.500.12556/RUL-86420 This link opens in a new window
UDC:504.05:656.61(043.2)
COBISS.SI-ID:7710049 This link opens in a new window
Publication date in RUL:03.11.2016
Views:3658
Downloads:706
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Ballast water management compliance monitoring - indicative methods
Abstract:
Vessels need ballast water to ensure their stability and manoeuvrability during their port and sailing operations when un-laden. Ballast water contains sediments, organisms and pathogens, which are transferred from one geographic location to another. Therefore, vessels are considered one of the primary pathways for the transfer of harmful aquatic organisms and pathogens. The D-2 regulation of the Ballast Water Management Convention allows the ships to discharge less organisms than specified in the D-2 standard to prevent its spread, transfer and the introduction of harmful aquatic organisms and pathogens around the globe. The Convention also requires inspections in order to verify vessels compliance with the requirements. Inspectors can take samples of the ballast water in order to perform a biological sample analysis test using indicative instruments, or to conduct a detailed test. We reviewed the possible methods of taking a representative sample of the ballast water for monitoring compliance with the Convention, and the indicative sample analysis tools. The key objective of this diploma was to evaluate the appropriateness of the selected tool Walz Water PAM for indicative analysis, which is used to identify living phytoplankton cells. The measurements of the instrument Walz Water PAM were compared with detailed analysis of samples in a laboratory. It was concluded that Walz Water PAM could be suitable for the indicative analysis of the vessels ballast water.

Keywords:graduation thesis, civil engineering, ballast water, sampling, control, compliance, convention, indicative methods

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back