Abstract
V teoretičnem delu magistrske naloge smo najprej povzeli zakonodajo s področja odvajanja in čiščenja odpadnih voda. Sledi opis biološkega čiščenja odpadnih voda in predstavitev različnih sistemov za biološko čiščenje odpadnih voda. Predstavili smo možne načine ravnanja s presežnim biološkim blatom, ki kot neizogiben stranski produkt nastaja pri biološkem čiščenju odpadnih voda. Teoretični del smo zaključili z opisom sistema odvajanja in čiščenja odpadnih voda v občini Zagorje ob Savi, pri čemer smo se osredotočili na proces čiščenja odpadnih voda na Centralni čistilni napravi Zagorje ob Savi. V eksperimentalnem delu smo na laboratorijskih SBR reaktorjih izvedli simulacijo delovanja realnega SBR reaktorja Centralne čistilne naprave Zagorje ob Savi. Z laboratorijskimi SBR reaktorji smo najprej ugotavljali, kako čas prezračevanja SBR reaktorjev vpliva na učinek čiščenja odpadne vode, nato pa smo učinke čiščenja odpadne vode laboratorijskih SBR reaktorjev primerjali z učinki čiščenja odpadne vode realnega SBR reaktorja Centralne čistilne naprave Zagorje ob Savi. Z napravo Automatic Methane Potential Test System II (AMPTS II) smo določili biometanski potencial presežnega biološkega blata Centralne čistilne naprave Zagorje ob Savi za dve različni organski obremenitvi v mezofilnem temperaturnem območju pri temperaturi 38 °C in v termofilnem temperaturnem območju pri temperaturi 55 °C. Na podlagi dobljenih rezultatov testa biometanskega potenciala smo analizirali smotrnost postavitve anaerobnega presnovališča. V zaključku magistrskega dela smo podali ugotovitve in možne predloge.

Language:Slovenian
Keywords:magistrska dela, odpadne vode, biološko čiščenje, presežno biološko blato, biometanski potencial, anaerobno presnovališče
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Place of publishing:Ljubljana
Publisher:[M. Juvan]
Year:2016
Number of pages:XVI, 100 str., 6 pril.
PID:20.500.12556/RUL-84765 This link opens in a new window
UDC:328.34:628.355(497.4)(043)
COBISS.SI-ID:7580257 This link opens in a new window
Publication date in RUL:19.09.2016
Views:3386
Downloads:608
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Research of the Operation Optimization of the Central Wastewater Treatment Plant Zagorje ob Savi
Abstract:
In the theoretical part of the Master's thesis we first summarized the legislation about the disposal and treatment of wastewaters. After this, there is a description of biological wastewater treatments and a presentation of the various systems for biological wastewater treatment. We presented the possible ways to deal with biological excess sludge, which appears as an inevitable side product of biological wastewater treatment. The theoretical part ends with a description of the system of disposal and treatment of wastewaters in the Municipality Zagorje ob Savi, where we focused on the process of wastewater treatment at the Central Wastewater Treatment Plant Zagorje ob Savi. In the experimental part we performed a simulation of the activity of the SBR reactor of the Central Wastewater Treatment Plant Zagorje ob Savi on the laboratory's SBR reactors. With the laboratory's SBR reactors we first established how the ventilation time of the SBR reactors influence the effects of the wastewater treatment and then we compared the effects of the wastewater treatment of the laboratory's SBR reactors with the effects of the wastewater treatment of the real SBR reactor of the Central Wastewater Treatment Plant Zagorje ob Savi. With the Automatic Methane Potential Test System II (AMPTS II) device we established the biomethane potential of the biological excess sludge of the Central Wastewater Treatment Plant Zagorje ob Savi for two different organic loads, in a mesophilic temperature zone at 38 °C and in a thermophilic temperature zone at 55 °C. On the basis of the obtained results of the biomethane potential test we analysed the expediency of setting up an anaerobic digester. In the conclusion of the thesis we introduced our findings and possible suggestions.

Keywords:master of science thesis, wastewater, biological treatment, biological excess sludge, biomethane potencial, anaerobic digester