Abstract
V pričujočem delu se ukvarjamo z razvojem integracijskega AD-pretvornika, pri čemer želimo doseči merilno negotovost manjšo od 10^-6. Na osnovi temeljite proučitve slabosti in prednosti obstoječih izvedb AD-pretvornikov smo izluščili ključne vire negotovosti. V osrednjem delu predlagamo izvirno rešitev, ki vpliv teh virov napak zmanjšuje pod zaznavno raven s ciljem, da je merilna negotovost merilnika s pomočjo lastnega umerjanja odvisna samo od negotovosti referenčne napetosti. Za umerjanje delov vezja smo uporabili pomožni AD-pretvornik, pri katerem smo dosegli merilno negotovost znotraj območja napake referenčnega merilnika. Pri glavnem AD-pretvorniku pa smo dosegli negotovost meritve (4,2 +/- 2,26)*10^-6.

Language:Slovenian
Keywords:AD-pretvornik, integrator, dvostrminski integracijski AD-pretvornik, večstrminski integracijski AD-pretvornik
Work type:Master's thesis/paper
Organization:FE - Faculty of Electrical Engineering
Year:2015
PID:20.500.12556/RUL-72307 This link opens in a new window
Publication date in RUL:11.09.2015
Views:2429
Downloads:594
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Self-calibrating, six-digit multiple-slope integrating AD converter
Abstract:
The thesis addresses development of integrating AD-converter, with goal uncertainty of 10^-6. Based on detailed study of weaknesses and advantages of existing solutions we extract the key sources of uncertainty. In the central part of this thesis we propose a novel solution, that inherently reduces the influence of this uncertainties. The main idea of our proposal is that by thorough self calibration the uncertainty of the reading of the instrument depends solely on the uncertainty of the reference voltage. For the purpose of calibration we introduce auxiliary AD converter, which measured uncertainty turned out to be in the range of uncertainty of the reference instrument. Achieved measurement uncertainty of the whole instrument including main AD converter is (4,2 +/- 2,26)*10^-6.

Keywords:AD-converter, integrator, dual-slope integrating AD-converter, multi-slope integrating AD-converter