izpis_h1_title_alt

AVTOMATIZIRANO MERJENJE DISAKOMODACIJSKEGA FAKTORJA TOROIDNIH JEDER
ID KRIVEC, MARTIN (Author), ID Bojkovski, Jovan (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (4,13 MB)
MD5: A7C6C207901E5EA947E4EC7699FD252F
PID: 20.500.12556/rul/531661af-5328-4c92-b606-f58e2c02e4c3

Abstract
Cilj diplomske naloge je izvesti avtomatizirano merjenje disakomodacijskega faktorja toroidnih jeder. Disakomodacijski faktor se meri z namenom zagotavljanja ustrezne permeabilnosti jedra pri končnem kupcu. Permeabilnost jedra upada s časom po določeni krivulji. Z meritvami v kratkem časovnem obdobju lahko predvidimo padec permeabilnosti čez daljše obdobje. V drugem poglavju je opisano fizikalno ozadje meritve. Tretje poglavje vsebuje povzetek standarda IEC 62044-2 (2005). V četrtem poglavju je predstavljen postopek priprave celotnega sistema za merjenje in opis posameznih elementov sistema, vključno s programsko opremo. Peto poglavje navaja zahteve za izdelavo aplikacije za avtomatizirano merjenje disakomodacijskega faktorja. V šestem poglavju so opisane vse faze aplikacije. Sedmo poglavje vsebuje opis možnih izboljšav in nadgradenj aplikacije. V zadnjem (osmem) poglavju so predstavljeni rezultati testnih meritev.

Language:Slovenian
Keywords:Avtomatizirano merjenje, disakomodacijski faktor, toroidna jedra, permeabilnost
Work type:Bachelor thesis/paper
Organization:FE - Faculty of Electrical Engineering
Year:2014
PID:20.500.12556/RUL-29439 This link opens in a new window
Publication date in RUL:09.09.2014
Views:1803
Downloads:523
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:AUTOMATED MEASUREMENT OF DISSACOMMODATION FACTOR OF TOROIDAL CORES
Abstract:
The aim of the thesis is to conduct automated measurement of dissacommodation factor of toroidal cores. Dissacommodation factor is measured to ensure adequate permeability of the core in the hands of the customer. Permeability of the core decreases with time at a certain curve. With measurements in a short period of time we can predict the fall of permeability over a longer period of time. The second chapter describes physical background of the measurement. Third section is a summary of IEC 62044-2 (2005) standard. The fourth chapter describes the process of preparing the entire system and describes the devices and the software used. The fifth chapter lists requirements for the application. The sixth chapter describes all phases of the application. The seventh chapter contains a description of potential improvements and upgrades. The last (eighth) chapter presents the results of test measurements.

Keywords:Automated measurement, dissacommodation factor, toroidal cores, permeability

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back