Details

Bacterial adhesion on orthopedic titanium implants coated with silver-doped hydroxyapatite and chitosan
ID Gartner, Urška (Author), ID Zore, Anamarija (Author), ID Matijaković Mlinarić, Nives (Author), ID Abram, Anže (Author), ID Štukelj, Roman (Author), ID Modic, Martina (Author), ID Leskovac, Andreja (Author), ID Petrović, Sandra (Author), ID Stanić, Vojislav (Author), ID Dahmen, Safia (Author), ID Gošnak Dahmane, Raja (Author), ID Bohinc, Klemen (Author)

.pdfPDF - Presentation file, Download (2,20 MB)
MD5: FC3C6406BA5352DFD31FFEA1E74358C6
URLURL - Source URL, Visit https://www.mdpi.com/1420-3049/31/19/3537 This link opens in a new window

Abstract
Orthopedic site infections remain a growing concern in implantology, particularly in light of rising antibiotic resistance. Identifying optimal, standardized antimicrobial treatments is increasingly challenging. Beyond the design and functional properties of orthopedic materials, key factors such as bacterial adhesion and genotoxicity must also be considered. To develop implant materials with enhanced antibacterial properties and biocompatibility, this study investigated titanium (Ti) surfaces coated with chitosan (CS) and silver-doped hydroxyapatite (AgHA) at weight ratios of 1:1, 1:2, and 2:1. The incorporation of silver ions into hydroxyapatite demonstrated potent antibacterial activity, achieving a greater than 99% reduction in Staphylococcus aureus (S. aureus) viability in solution after just two hours of incubation, effectively inhibiting further bacterial growth. Furthermore, CS coatings combined with AgHA significantly reduced S. aureus adhesion and proliferation on Ti surfaces, with over 96% reduction in total bacterial viability. Further biological evaluation was performed on the CS:AgHA = 2:1 coating, selected for its favorable surface and antibacterial characteristics. Genotoxicity and cytotoxicity assessments using human peripheral blood lymphocytes showed no significant increase in micronuclei incidence for either uncoated Ti or CS:AgHA = 2:1-coated surfaces. Additionally, cell viability remained above 84%, indicating favorable biocompatibility under the experimental conditions used. Overall, these findings highlight the potential of CS:AgHA = 2:1 composite coatings for further investigation in antibacterial orthopedic implant applications.

Language:English
Keywords:bacterial adhesion, titanium implants, chitosan
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:ZF - Faculty of Health Sciences
Publication status:Published
Publication version:Version of Record
Publication date:01.01.2026
Year:2026
Number of pages:21 str.
Numbering:Vol. 31, issue 19, art. 3537
PID:20.500.12556/RUL-191387 This link opens in a new window
UDC:544
ISSN on article:1420-3049
DOI:10.3390/molecules31193537 This link opens in a new window
COBISS.SI-ID:305721347 This link opens in a new window
Publication date in RUL:17.11.2026
Views:35
Downloads:9
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Molecules
Shortened title:Molecules
Publisher:MDPI
ISSN:1420-3049
COBISS.SI-ID:18462981 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Projects

Funder:Other - Other funder or multiple funders
Funding programme:Ministry of Science, Technological Development and Innovation of the Republic of Serbia
Project number:451-03-33/2026-03/200017
Name:451-03-33/2026-03/200017

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:P3-0388-2022
Name:Mehanizmi varovanja zdravja