Urban overheating is spatially heterogeneous, meaning that the warmest surfaces are not necessarily the highest-priority areas for siting blue-green infrastructure (BGI). The aim of this study was to develop a transparent and reproducible procedure for identifying areas where recurring surface thermal load coincides with high socio-spatial need and a pronounced biophysical deficit of BGI, using the City Municipality of Ljubljana (MOL) as a case study. The analysis was based on 174 summer satellite scenes acquired by Landsat and ECOSTRESS between 2018 and 2025, and on a grid of 100 × 100 m cells. The modular approach combined multi-temporal analysis of land surface temperature (LST), modelling with a generalised additive model (GAM) and the LightGBM algorithm, and assessments of socio-spatial need and the biophysical deficit of BGI. Predictive performance was assessed using spatial block cross-validation. The narrower analytical area was warmer than the wider MOL area in most observations, particularly during the day, while temperature differences were smaller at night. The proportions of impervious surfaces and tree cover emerged as important predictors of LST. LightGBM achieved better predictive performance than GAM across the wider analytical area in all five sensor–time combinations, although spatial autocorrelation remained in the residuals of both models. High socio-spatial need and high biophysical deficit overlapped across 40.78 % of the narrower analytical area, while a stricter selection identified 179 priority cells (1.59 % of the area). These findings support directing further spatial assessment towards areas where surface thermal load, socio-spatial need and a lack of cooling elements coincide.
|