Details

Eksperimentalna primerjava termografskih fosforjev za merjenje temperature na osnovi luminiscencnega upada
ID Semelbauer, Klemen (Author), ID Mlačnik, Vid (Author), ID Pušnik, Igor (Author), ID Beguš, Samo (Author)

.pdfPDF - Presentation file, Download (2,81 MB)
MD5: E59FF2564B6C403E9717209C07882CA4
URLURL - Source URL, Visit https://erk.fe.uni-lj.si/2026/papers/semelbauer(eksperimentalna_primerjava).pdf This link opens in a new window

Language:Slovenian
Keywords:termografski fosfor, čas upada, merjenje temperature
Typology:1.08 - Published Scientific Conference Contribution
Organization:FE - Faculty of Electrical Engineering
Publication status:Published
Year:2026
Number of pages:Str. 353-356
PID:20.500.12556/RUL-190820 This link opens in a new window
UDC:621.317
ISSN on article:2591-0442
COBISS.SI-ID:293090819 This link opens in a new window
Publication date in RUL:04.11.2026
Views:20
Downloads:3
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a proceedings

Title:Zbornik petintridesete mednarodne Elektrotehniške in računalniške konference ERK 2026
COBISS.SI-ID:292311811 This link opens in a new window

Record is a part of a journal

Title:Zbornik ... mednarodne Elektrotehniške in računalniške konference
Publisher:Slovenska sekcija IEEE, Fakulteta za elektrotehniko
ISSN:2591-0442
COBISS.SI-ID:291620352 This link opens in a new window

Secondary language

Language:English
Title:Experimental comparison of thermographic phosphors for temperature measurement based on luminescence decay
Abstract:
Four thermographic phosphors, QMK24/N-C7, QMK66/F-A1, MK24/F-X and EQD25/F-U1, were applied to brass substrates using an inorganic Ceramabind 643-2 binder. A thin brush coating and a syringe-applied coating were compared. The samples were spectrally characterized under 405 nm and 365 nm excitation and tested in an automated dual-channel phosphor-thermometry system with detection near 635 nm and 660 nm. Only QMK24/N-C7 and EQD25/F-U1 provided a sufficient signalto-noise ratio for stable exponential fitting at several temperatures. Values digitized from the recorded plots indicate sensitivities from −15, 6 to −20, 1 µs/ ◦C for QMK24/N-C7 and from −7, 8 to −8, 4 µs/ ◦C for EQD25/FU1. QMK24/N-C7 was nominally more sensitive, while EQD25/F-U1 produced higher SNR and therefore more repeatable temperature characteristics. The results show that spectral matching, coating thickness and coating homogeneity must be considered together when selecting a phosphor for a practical measurement system.

Keywords:thermographic phosphor, decay time, temperature measurement

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back