Radon is a naturally occurring radioactive gas that may accumulate in enclosed spaces and pose a significant health risk to employees. The purpose of this master’s thesis was to determine radon concentrations in selected basement rooms of the Faculty of Chemistry and Chemical Technology at the University of Ljubljana, analyse their temporal and spatial variations, and assess employee exposure to radon at selected workplaces.
Measurements were carried out during winter and summer measurement periods using active radon monitors and passive CR-39 track detectors. Passive measurements were conducted at ten measurement locations, while active measurements were performed in the chemical dispensing room, the cleaners’ changing room, and the equipment storage room. The active measurements were used to analyse temporal variations in radon concentrations, average daily profiles, and differences between working and non-working hours. Available microclimatic and operational data from the building management system were also used as supplementary information for the interpretation of the results.
The results showed low radon concentrations in all investigated rooms. Mean concentrations obtained from active measurements ranged from 16 to 23 Bq/m³ in winter and from 12 to 28 Bq/m³ in summer. Likewise, the passive measurements did not indicate elevated radon levels. The comparison between working and non-working hours did not reveal a consistent pattern, as concentrations were lower during working hours only in the chemical dispensing room, while the opposite pattern was observed in the other two actively monitored rooms. Seasonal differences were also inconsistent, as concentrations were higher in winter than in summer in two of the three actively monitored rooms, whereas a higher mean concentration was observed in the cleaners’ changing room during summer.
Based on the measurements, no increased radon concentrations were identified at the investigated workplaces during the study period. The measured concentrations were below the reference level of 300 Bq/m³, although it should be noted that this reference level applies to the annual average radon concentration. The results also demonstrate the temporal and spatial variability of radon concentrations and indicate the importance of periodic monitoring, particularly in basement workplaces.
|