Abstract
V zaključni nalogi je obravnavana kalibracija dajalnika zasuka na proizvodni napravi z uporabo laserskega interferometričnega sistema. Definiran je bil merilni postopek, na podlagi katerega sta bila določena pogrešek in merilna negotovost sistema. Rezultati kažejo prisotnost sistematskega pogreška in histereze. Ugotovljen je vpliv stabilizacije sistema na ponovljivost meritev, pri čemer zadostna stabilnost omogoča zanesljiv zajem podatkov tudi brez natančne časovne sinhronizacije merilnih signalov.

Language:Slovenian
Keywords:kalibracija, dajalniki zasuka, laserska interferometrija, merilni pogrešek, merilna negotovost
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Publication status:Published
Publication version:Version of Record
Place of publishing:Ljubljana
Publisher:[P. Scozzai]
Year:2026
Number of pages:XIII, 35 f.
PID:20.500.12556/RUL-189322 This link opens in a new window
UDC:621.713.3:531.715(043.2)
COBISS.SI-ID:294041091 This link opens in a new window
Publication date in RUL:03.10.2026
Views:100
Downloads:44
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Calibration of the rotary encoder on a production device
Abstract:
This thesis addresses the calibration of an angular encoder installed on a production device using a laser interferometric system. A measurement procedure was defined, based on which the measurement error and uncertainty of the system were determined. The results show the presence of systematic error and hysteresis effects. An influence of system stabilization on measurement repeatability was identified, where sufficient stabilization enables reliable data acquisition without the need for precise time synchronization between measurement signals.

Keywords:calibration, angular encoders, laser interferometry, measurement error, measurement uncertainty