Positron emission tomography (PET) is an imaging modality in nuclear medicine primarily focused on imaging physiological processes within the body of a patient. One of the focuses in the development of PET detectors is the use of time-of-flight (TOF) information during image reconstruction. In order to achieve improvements in coincidence time resolution (CTR) every part of the detector requires improvement. As the CTR is improved, new possibilities emerge in the construction and use of PET scanners, such as open geometry and flat panel scanner configurations. The latter design could bring several advantages over the conventional cylindrical scanners, the principal being the reduction of the cost of the device. The new geometry also introduces several new challenges both in use and assessment of the scanner. The optimisation of the novel scanner design was performed using Monte Carlo simulations, where various scanner configurations were compared to a reference scanner using various performance metrics for image quality with both standard and novel phantoms. As the novel geometry presented new challenges, such as the increased parallax error and reduced angular coverage, additional corrections were considered during image reconstruction alongside the study of various parameters used in the reconstruction process. Experimental measurements were performed using a pair of detector elements, with the aim of characterisation of the scintillators and photodetectors and evaluating the effects of the experimental parameters such as different bias voltages, optical coupling agents and acquisition hardware on the measured CTR.

Language:English
Keywords:Positron emission tomography, Time-of-flight, Monte Carlo simulations, Coincidence time resolution, Experimental measurements
Work type:Doctoral dissertation
Typology:2.08 - Doctoral Dissertation
Organization:FMF - Faculty of Mathematics and Physics
Year:2026
PID:20.500.12556/RUL-189150 This link opens in a new window
COBISS.SI-ID:293663491 This link opens in a new window
Publication date in RUL:02.10.2026
Views:240
Downloads:66
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:Slovenian
Title:Razvoj detektorjev za pozitronsko emisijsko tomografijo z meritvijo časa preleta v ploščati geometriji
Abstract:
Pozitronska emisijska tomografija (PET) je modaliteta slikanja v nuklearni medicini, ki omogoča slikanje fizioloških procesov v telesu pacienta. Ena izmed smeri razvoja detektorjev za PET je uporaba meritve časa preleta v rekonstrukcijah slik. Za izboljšavo časovne ločljivosti (CTR) je potrebna izboljšava vsakega dela detektorja. Z izboljšavo CTR se odprejo nove možnosti v izdelavi PET skenerjev, na primer odprta geometrija in ploščata geometrija detektorjev. Slednji bi lahko privedli do več prednosti pred konvencionalnimi cilindričnimi skenerji; glavno med njimi bi bilo znižanje cene naprave. Nova geometrija privede tudi do mnogih novih izzivov v uporabi in evalvaciji zmogljivosti skenerjev. Optimizacija zasnove skenerjev je bila izvedena z Monte Carlo simulacijami. Različne konfiguracije skenerjev so bile primerjane z referenčnim skenerjem z uporabo več metrik za oceno kvalitete slike tako s standardnimi kot tudi novimi fantomi. Zaradi izzivov, ki jih predstavlja ta geometrija, predvsem napaka zaradi paralakse in nepopolne kotne pokritosti, so bili pri rekonstrukciji upoštevani dodatni popravki poleg študije različnih rekonstrukcijskih parametrov. Eksperimentalne meritve so bile opravljene z enim parom detektorskih elementov. Cilj meritev je bila karakterizacija scintilatorjev in fotodetektorjev ter ocena učinkov eksperimentalnih parametrov kot so napetost na fotodetektorju, mediji za optično sklopitev in oprema za zajem na izmerjeno časovno ločljivost.

Keywords:Pozitronska emisijska tomografija, meritev časa preleta, Monte Carlo simulacije, koincidenčna časovna ločljivost, eksperimentalne meritve