Abstract
Diplomsko delo obravnava tehnološke izzive brezkontaktnega merjenja srčnega utripa z metodo oddaljene fotopletizmografije rPPG (angl. remote photoplethysmography) v zahtevnem, dinamičnem scenariju simulatorja vožnje. V teoretičnem delu so predstavljeni fiziološki temelji merjenja srčne aktivnosti, dikromatski model odboja svetlobe od kože ter pet klasičnih metod rPPG za ekstrakcijo pulznega signala: GREEN, CHROM (angl. Chrominance based), PBV (angl. Pulse Blood Volume), 2SR (angl. Spatial Subspace Rotation) in POS (angl. Plane Orthogonal to Skin). Podrobneje so obravnavani tudi ključni izzivi fotopletizmografije, med drugim izbira območja zanimanja ROI (angl. Region Of Interest), vpliv gibanja subjekta ter dolžina analiziranega okna. V eksperimentalnem delu je bila izvedena sistematična analiza petih metod na podatkovni zbirki 29 subjektov, posnetih v simulatorju vožnje, ločeno za scenarija mirovanja in vožnje ter na štirih anatomskih območjih obraza: čelo, levo in desno lice ter vrat. Rezultati so pokazali, da metodi POS in 2SR dosegata najboljšo točnost, kar je bilo tudi statistično potrjeno s Friedmanovim in post-hoc Nemenyi testom. Na čelu v mirovanju povprečni MAE (angl. Mean Absolute Error) znaša 3,79 bpm za metodo POS oziroma 4,70 bpm za metodo 2SR. Izbira območja ROI se je izkazala za pomemben, statistično značilen dejavnik, pri čemer je čelo dosegalo najboljše rezultate (MAE 3,79 bpm), vrat pa najslabše (MAE 16,51 bpm). Dodatna analiza je pokazala, da izključitev petih subjektov z zakritim ROI zaradi očal za sledenje pogleda zniža MAE za področje čela za približno tretjino, odstranitev ročno zaznanih intervalov gibanja pri izbranem subjektu pa točnost na čelu in licih izboljša tudi do 73%. Primerjava z literaturo je pokazala, da so rezultati tega dela na zahtevnejših, manj kontroliranih podatkovnih zbirkah primerljivi ali celo boljši od objavljenih vrednosti, medtem ko so v primerjavi s kratkimi, kontroliranimi laboratorijskimi posnetki nekoliko slabši.

Language:Slovenian
Keywords:rPPG, oddaljena fotopletizmografija, srčni utrip, simulator vožnje, MAE, GREEN, CHROM, PBV, 2SR, POS
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FE - Faculty of Electrical Engineering
Year:2026
PID:20.500.12556/RUL-186932 This link opens in a new window
COBISS.SI-ID:291036931 This link opens in a new window
Publication date in RUL:07.09.2026
Views:241
Downloads:144
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Technological challenges of remote photoplethysmography
Abstract:
This diploma thesis addresses the technological challenges of contactless heart rate measurement using remote photoplethysmography rPPG in the demanding, dynamic scenario of a driving simulator. The theoretical part presents the physiological foundations of measuring cardiac activity, the dichromatic reflection model of light from skin, and five classical rPPG methods for pulse signal extraction: GREEN, CHROM (Chrominance based), PBV (Pulse Blood Volume), 2SR (Spatial Subspace Rotation), and POS (Plane Orthogonal to Skin). Key challenges of photoplethysmography are also examined in detail, including ROI (Region Of Interest) selection, the influence of subject motion, and analysis window length. In the experimental part, a systematic analysis of the five methods was performed on a dataset of 29 subjects recorded in a driving simulator, separately for the baseline and driving scenarios and across four anatomical facial regions: forehead, right and left cheek, and neck. The results showed that the POS and 2SR methods achieved the best accuracy, which was also statistically confirmed by the Friedman test and post-hoc Nemenyi test. At the forehead during baseline, the average MAE (Mean Absolute Error) was 3,79 bpm for the POS method and 4,70 bpm for the 2SR method. The choice of ROI proved to be an important, statistically significant factor, with the forehead achieving the best results (MAE 3,79 bpm) and the neck the worst (MAE 16,51 bpm). Additional analysis shows that excluding five subjects with an occluded ROI due to eye-tracking glasses reduced the MAE at the forehead by approximately one third, while removing manually identified motion intervals for a selected subject improved accuracy at the forehead and cheeks by up to 73%. Comparison with the literature showed that the results of this work are comparable to, or even better than, published values on more demanding, less controlled datasets, while being somewhat worse compared to short, controlled laboratory recordings.

Keywords:rPPG, remote photoplethysmography, heart rate, driving simulator, MAE, GREEN, CHROM, PBV, 2SR, POS