Abstract
Laserski sistemi za zaznavanje, kot sta LiDAR in NLOS, vse pogosteje uporabljajo valovno dolžino 1550 nm, ki velja za varnejšo za oči, ker se absorbira prej in ne doseže mrežnice, vendar še vedno lahko poškoduje roženico. Mejne vrednosti za uporabo laserjev pri tej valovni dolžini so porazdeljene po različnih standardih in smernicah, zato hitra presoja varnosti takega sistema ni mogoča. Pregledali smo literaturo in v tabelah zbrali največje dopustne izpostavljenosti za zvezno delovanje, posamezen pulz in ponavljajoče se pulze in jih primerjali še z eksperimentalno določenimi pragovi poškodbe roženice. Nato smo preverili varnost parametrov na dveh objavljenih sistemih NLOS. Največja dopustna izpostavljenost znaša 100 mW/cm² za zvezno osvetljevanje in 1 J/cm² za posamezen pulz v območju od 1 ns do 10 s. Pri ponavljajočih se pulzih je največkrat restriktivno drugo pravilo. Za pulze, krajše od 1 ns, mejna vrednost ni točno določena.

Language:Slovenian
Keywords:laserska varnost, valovna dolžina 1550 nm, absorpcija v vodi, prag poškodbe roženice, največja dopustna izpostavljenost, LiDAR, NLOS
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[J. Stare]
Year:2026
Number of pages:XIII, 24 f.
PID:20.500.12556/RUL-186175 This link opens in a new window
UDC:621.375.826:614.893(043.2)
COBISS.SI-ID:289426179 This link opens in a new window
Publication date in RUL:28.08.2026
Views:136
Downloads:37
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Laser safety at wavelengths around 1,5 µm
Abstract:
Laser sensing systems such as LiDAR and NLOS increasingly use light at a wavelength of 1550 nm, which is considered safer for the eye because it is absorbed in water before it can reach the retina. However, it can still damage the cornea. The exposure limits for such wavelength are spread across various standards and guidelines, so a quick safety assessment of a provided system is not possible. We reviewed the literature and compiled the maximum permissible exposures for continuous wave lasers, single pulses and repetitive pulses into tables and compared them with experimentally determined corneal damage thresholds. We then examined the safety of two published NLOS systems. The maximum exposure is 100 mW/cm² for continuous exposure and 1 J/cm² for a single pulse in the duration range from 1 ns to 10 s. For repetitive pulses, the second rule is usually the most restrictive. For pulses shorter than 1 ns no direct limit is specified.

Keywords:laser safety, wavelength 1550 nm, water absorption, corneal damage threshold, maximum permissible exposure, LiDAR, NLOS