Details

Uporaba fluorescenčnega barvila FITC za spremljanje infektivnosti bakteriofagov
ID Ulaga Sterle, Cene (Author), ID Podgornik, Aleš (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (1,32 MB)
MD5: 07669AC94FE7965C34C8FE30B185C1B7

Abstract
Bakteriofagi so virusi bakterij, ki se danes vse pogosteje uporabljajo v biotehnologiji, medicini in živilski industriji. Za te namene je ključnega pomena natančno in hitro določanje njihove koncentracije ter spremljanje stabilnosti skozi čas. Naše delo poskuša ovrednotiti uporabo fluorescenčnega barvila fluorescein izotiocianat (FITC) za spremljanje infektivnosti morfološko različnih bakteriofagov T4, T7 in ϕ6. Po kovalentnem označevanju njihovih kapsidnih proteinov smo merili intenziteto fluorescence. Preučili smo vpliv kemijske modifikacije na ohranjanje infektivnosti fagov ter ugotovili, da je postopek barvanja zmanjšal infektivnost bakteriofaga T7, medtem ko sta faga T4 in ϕ6 ohranila stabilen titer. Korelacija med intenziteto fluorescence in titrom PFU v svežih vzorcih je bila dobra, z najvišjo vrednostjo pri bakteriofagu T7. V drugem delu raziskave smo časovno spremljali stabilnost bakteriofagov 624 ur. Rezultati so pokazali, da sta bila tako signal fluorescence kot infektivnost, merjena s PFU, v hladilniku pri 4°C stabilna in v dobri korelaciji, na sobni temperaturi (25°C) in ob stalni osvetlitvi pa je prišlo do kritičnega razkoraka med fluorescenco in PFU. Infektivnost je sicer različno pri vseh virusih, a povsod hitro padla na nič, medtem ko je bil fluorescentni signal še vedno zaznaven. To nakazuje, da fluorescenca FITC meri prisotnost virusne biomase, ne pa biološke funkcionalnosti, kar v neoptimalnih pogojih vodi do napačnih rezultatov. Metoda je uporabna kot hitro dopolnilno orodje za sveže vzorce, medtem ko za natančno določanje titra aktivnih delcev metoda PFU ostaja nenadomestljiv standard.

Language:Slovenian
Keywords:bakteriofagi, fluorescenčno označevanje, FITC, infektivnost, metoda štetja plakov (PFU), stabilnost virusov
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:BF - Biotechnical Faculty
Year:2026
PID:20.500.12556/RUL-185833 This link opens in a new window
COBISS.SI-ID:288461315 This link opens in a new window
Publication date in RUL:21.08.2026
Views:186
Downloads:63
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Use of FITC fluorescent dye for monitoring bacteriophage infectivity
Abstract:
Bacteriophages are bacterial viruses that have shown increasing use in recent years across medicine, food industry, and as research tools. For these purposes, accurate and rapid determination of their concentration and monitoring of their stability over time are of crucial importance. Our work attempts to evaluate the use of the fluorescent dye fluorescein isothiocyanate (FITC) for tracking the infectivity of morphologically distinct bacteriophages T4, T7, and ϕ6. Following the covalent labeling of capsid proteins, we measured the fluorescence intensity. We investigated the effect of chemical modification on the preservation of phage infectivity and found that the staining procedure reduced the infectivity of bacteriophage T7, whereas did not reduce the infectivity of phages T4 and ϕ6. The correlation between fluorescence intensity and PFU titer in fresh samples was good, reaching its highest value in bacteriophage T7. In the second part of the study, we monitored the stability of the bacteriophages over time for 624 hours. The results showed that both the fluorescence signal and infectivity, measured by PFU, were stable and well-correlated in a refrigerator at 4 °C; however, a critical discrepancy emerged at room temperature (25 °C) under constant illumination. Infectivity dropped quickly to zero in all viruses, albeit at different rates, while the fluorescent signal remained detectable. This indicates that FITC fluorescence measures the presence of viral biomass rather than biological functionality, causing misleading results under non-optimal conditions. The method is useful as a rapid complementary tool for fresh samples, whereas the PFU method remains an indispensable standard for the precise determination of active particle titers.

Keywords:bacteriophages, fluorescent labeling, FITC, infectivity, plaque assay (PFU), viral stability

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back