Details

Comparative analysis of lateral cervical radiographic imaging quality with and without anti-scatter grid application
ID Lučić, Daša (Author), ID Jurša, Laura (Author), ID Alukić, Erna (Author), ID Mekiš, Nejc (Author)

.pdfPDF - Presentation file, Download (489,02 KB)
MD5: DDE4433F73FBAE3F69C4FBCEB15220C6
URLURL - Source URL, Visit https://www.sciencedirect.com/science/article/pii/S0969804326000436 This link opens in a new window

Abstract
Purpose This study investigated the effects of anti-scatter grid removal on radiation dose, image quality, and anatomical visibility in lateral (LAT) cervical spine imaging. Methods A two-part prospective study was conducted. In the phantom study, an anthropomorphic head-torso phantom with lard simulating extra fatty tissue of 2–10 cm in 2 cm increments was imaged using protocols with and without an anti-scatter grid. In the clinical study, 80 patients were randomly divided into two groups: half were imaged with an anti-scatter grid, and half without. Data collected included gender, body mass index (BMI), Dose Area Product (DAP), tube voltage (kV), current-time product (mAs), filtration, neck width, and use of Automatic Exposure Control (AEC). Effective dose (ED) and dose to selected organs were calculated using PCXMC 2.0 software. Two traumatologists and one radiologist evaluated all phantom and patient images according to European guidelines using a four-point scale (1 = diagnostically inadequate image; 4 = excellent image quality). Results In the phantom study, removal of the anti-scatter grid reduced mean DAP by 52.1 % (p < 0.001) without affecting diagnostic adequacy; soft tissue-bone contrast improved (p = 0.009). In the patient study, removal of the anti-scatter grid reduced mean DAP and ED by 63.1 % and 61.7 %, respectively (both p < 0.001). All organ doses were significantly lower (p < 0.001). Soft tissue visibility improved by 12.5 % (p = 0.011), and soft tissue-bone contrast improved by 9.1 % (p = 0.007) without the anti-scatter grid. No other quality criteria differed significantly. Conclusion In both phantom and patient studies, removal of the anti-scatter grid resulted in significant dose reduction while maintaining or improving image quality. These results are consistent with previous findings and support the As Low As Reasonably Achievable (ALARA) principle. Omitting the anti-scatter grid in LAT cervical spine imaging reduces dose by about 60 % without compromising diagnostic quality. Routine use in clinical practice is recommended to increase patient safety.

Language:English
Keywords:cervical spine radiography, dose reduction, image quality, anti-scatter grid
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:ZF - Faculty of Health Sciences
Publication status:Published
Publication version:Version of Record
Publication date:01.04.2026
Year:2026
Number of pages:5 str.
Numbering:Vol. 230, art. 112459
PID:20.500.12556/RUL-178930 This link opens in a new window
UDC:616-07
ISSN on article:1872-9800
DOI:10.1016/j.apradiso.2026.112459 This link opens in a new window
COBISS.SI-ID:266902019 This link opens in a new window
Publication date in RUL:02.02.2026
Views:367
Downloads:270
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Applied radiation and isotopes
Publisher:Elsevier
ISSN:1872-9800
COBISS.SI-ID:23195141 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back