Details

Neupoštevanje predpostavk in druge omejitve pri uporabi Bland-Altman analize
ID KUŠAR, MAŠA (Author), ID Pohar Perme, Maja (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (15,71 MB)
MD5: E8D837DB95CC6265EF6F469ACD57D45A

Abstract
Uporaba najosnovnejše analize Bland-Altman zahteva upoštevanje nekaterih predpostavk, ki v praksi pogosto niso izpolnjene. Poleg tega smiselna uporaba analize Bland-Altman vključuje uporabo ponovljenih meritev z isto metodo pri istem posamezniku, kar v osnovnem primeru analize ni upoštevano. Da bi omogočili ustrezno analizo ponovljenih podatkov, ter analizo v primeru kršenih predpostavk, avtorja predlagata nekatere popravke, ki pa v medicinski literaturi običajno niso uporabljeni. Prav tako ti popravki pogosto niso na voljo v programski opremi, npr. v R knjižnicah za analizo Bland-Altman. Posledica neuporabe popravkov je napačna ocena standardnega odklona razlik med metodama in zato napačna ocena mej ujemanja med metodama. Takšna napaka lahko pripelje do uporabe neustreznih metod (v primeru preozkih mej ujemanja) ter do neupravičenega zavračanja ustreznih metod (v primeru preširokih mej ujemanja). Cilj tega dela je oceniti posledice opustitve uporabe teh popravkov na zanesljivost pridobljenih rezultatov.

Language:Slovenian
Keywords:merilne metode, analiza Bland Altman, ponovljene meritve
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FE - Faculty of Electrical Engineering
Year:2026
PID:20.500.12556/RUL-177722 This link opens in a new window
COBISS.SI-ID:265369859 This link opens in a new window
Publication date in RUL:05.01.2026
Views:555
Downloads:269
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Assumptions and limitations of Bland Altman analysis
Abstract:
The use of the simplest version of Bland-Altman analysis requires some assumptions that are often not met in clinical practice. Furthermore, a complete Bland Altman analysis requires the use of repeated measurements with the same method, which is not possible with the simplest approach. To allow an appropriate analysis of repeated measurements, and to address unmet assumptions, the authors suggest a series of simple corrections. However, these are commonly not used in existing literature, nor are they available in commonly used software, such as R packages. When these corrections are not used, the estimate of the standard deviation of differences between methods is wrong, leading to a wrong estimate of the limits of agreement. This error can lead to the acceptance of inadequate methods (when the limits of agreement are too narrow) or the rejection of adequate methods (when the limits of agreement are too wide). The aim of this thesis is to estimate how the reliability of Bland Altman results is affected by the omission of the proposed corrections.

Keywords:measurement methods, Bland Altman analysis, repeated measurements

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back