Details

vOARiability : interobserver and intermodality variability analysis in OAR contouring from head and neck CT and MR images
ID Podobnik, Gašper (Author), ID Ibragimov, Bulat (Author), ID Peterlin, Primož (Author), ID Strojan, Primož (Author), ID Vrtovec, Tomaž (Author)

.pdfPDF - Presentation file, Download (6,19 MB)
MD5: C8F9738DA0CFB483FEF6C1C70BD372D7
URLURL - Source URL, Visit https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.16924 This link opens in a new window

Abstract
Background Accurate and consistent contouring of organs-at-risk (OARs) from medical images is a key step of radiotherapy (RT) cancer treatment planning. Most contouring approaches rely on computed tomography (CT) images, but the integration of complementary magnetic resonance (MR) modality is highly recommended, especially from the perspective of OAR contouring, synthetic CT and MR image generation for MR-only RT, and MR-guided RT. Although MR has been recognized as valuable for contouring OARs in the head and neck (HaN) region, the accuracy and consistency of the resulting contours have not been yet objectively evaluated. Purpose To analyze the interobserver and intermodality variability in contouring OARs in the HaN region, performed by observers with different level of experience from CT and MR images of the same patients. Methods In the final cohort of 27 CT and MR images of the same patients, contours of up to 31 OARs were obtained by a radiation oncology resident (junior observer, JO) and a board-certified radiation oncologist (senior observer, SO). The resulting contours were then evaluated in terms of interobserver variability, characterized as the agreement among different observers (JO and SO) when contouring OARs in a selected modality (CT or MR), and intermodality variability, characterized as the agreement among different modalities (CT and MR) when OARs were contoured by a selected observer (JO or SO), both by the Dice coefficient (DC) and 95-percentile Hausdorff distance (▫$HD_95$▫). Results The mean (±standard deviation) interobserver variability was 69.0 ± 20.2% and 5.1 ± 4.1 mm, while the mean intermodality variability was 61.6 ± 19.0% and 6.1 ± 4.3 mm in terms of DC and ▫$HD_95$▫, respectively, across all OARs. Statistically significant differences were only found for specific OARs. The performed MR to CT image registration resulted in a mean target registration error of 1.7 ± 0.5 mm, which was considered as valid for the analysis of intermodality variability. Conclusions The contouring variability was, in general, similar for both image modalities, and experience did not considerably affect the contouring performance. However, the results indicate that an OAR is difficult to contour regardless of whether it is contoured in the CT or MR image, and that observer experience may be an important factor for OARs that are deemed difficult to contour. Several of the differences in the resulting variability can be also attributed to adherence to guidelines, especially for OARs with poor visibility or without distinctive boundaries in either CT or MR images. Although considerable contouring differences were observed for specific OARs, it can be concluded that almost all OARs can be contoured with a similar degree of variability in either the CT or MR modality, which works in favor of MR images from the perspective of MR-only and MR-guided RT.

Language:English
Keywords:variability analysis, contouring, organs-at-risk, computed tomography, magnetic resonance, radiotherapy, head and neck cancer
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FE - Faculty of Electrical Engineering
Publication status:Published
Publication version:Version of Record
Year:2024
Number of pages:Str. 2175-2186
Numbering:Vol. 51, no. 3
PID:20.500.12556/RUL-173359 This link opens in a new window
UDC:004.93
ISSN on article:0094-2405
DOI:10.1002/mp.16924 This link opens in a new window
COBISS.SI-ID:181670147 This link opens in a new window
Publication date in RUL:16.09.2025
Views:167
Downloads:72
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Medical physics
Shortened title:Med. phys.
Publisher:American Institute of Physics
ISSN:0094-2405
COBISS.SI-ID:25924096 This link opens in a new window

Licences

License:CC BY-NC-ND 4.0, Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
Link:http://creativecommons.org/licenses/by-nc-nd/4.0/
Description:The most restrictive Creative Commons license. This only allows people to download and share the work for no commercial gain and for no other purposes.

Secondary language

Language:Slovenian
Keywords:analiza variabilnosti, orisovanje, kritični organi, računalniška tomografija, magnetna resonanca, radioterapija, rak glave in vrat

Projects

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:J2-1732
Name:Računalniško podprta analiza medicinskih slik za načrtovanje zdravljenja s protonsko in radioterapijo

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:P2-0232
Name:Analiza biomedicinskih slik in signalov

Funder:ARIS - Slovenian Research and Innovation Agency
Project number:P3-0307
Name:Rak glave in vratu - analiza bioloških značilnosti in poskus izboljšanja zdravljenja

Funder:Novo Nordisk Foundation
Project number:NFF20OC0062056
Name:Leveraging artificial intelligence for pancreatic cancer diagnosis, treatment planning and treatment outcome prediction

Funder:Institute of Oncology Ljubljana
Project number:ERID-EK/139

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back