Details

Unbalanced magnetic pull in an 18-slot/8-pole dual three-phase machine under different modes of operation
ID Drobnič, Klemen (Author), ID Fišer, Rastko (Author)

.pdfPDF - Presentation file, Download (2,31 MB)
MD5: A24FF56248EB2494957CF8D1218091EF
URLURL - Source URL, Visit https://www.emerald.com/insight/content/doi/10.1108/compel-09-2024-0402/full/html This link opens in a new window

Abstract
Purpose – This paper aims to analyze the emergence and impact of unbalanced magnetic pull (UMP) in an 18-slot/8-pole dual three-phase permanent magnet synchronous machine (DTM) during post fault operation (PFO) and synthetic loading operation (SLO). Understanding UMP in these specific operating modes is important for ensuring mechanical integrity of the electric drive. Design/methodology/approach – The authors conducted a series of finite element method (FEM) simulations to investigate UMP under PFO, where only one winding set is active, and SLO, where winding sets are energized in the opposite senses compared to normal operation. They examined the mechanisms leading to UMP and quantitatively assessed its magnitude. Findings – The authors' simulations reveal that UMP arises due to interactions between field harmonics with differing spatial orders, specifically the 4th and 5th harmonics during PFO and SLO. The presence of both odd and even harmonics in the machine’s field spectrum is a decisive factor in UMP generation. They found that while UMP increases bearing stress, it does not compromise the mechanical integrity. Research limitations/implications – Their analysis is based on FEM simulations and focuses on specific operating modes (PFO and SLO). Future work could explore other slot/pole combinations to generalize the findings. Originality/value – This study provides new insights into the behavior of UMP in DTM under non-typical operating modes, contributing to the broader understanding of machine performance and durability.

Language:English
Keywords:unbalanced magnetic pull, dual three-phase machine, multiphase machine, fractional-slot winding, synthetic loading, post-fault operation
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FE - Faculty of Electrical Engineering
Publication status:Published
Publication version:Version of Record
Year:2025
Number of pages:Str. 274-289
Numbering:Vol. 44, no. 3
PID:20.500.12556/RUL-169225 This link opens in a new window
UDC:621.313/.314
ISSN on article:0332-1649
DOI:10.1108/COMPEL-09-2024-0402 This link opens in a new window
COBISS.SI-ID:233148163 This link opens in a new window
Publication date in RUL:19.05.2025
Views:543
Downloads:291
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Compel
Shortened title:Compel
Publisher:Emerald
ISSN:0332-1649
COBISS.SI-ID:1659652 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:magnetna neuravnoteženost, dvojni trifazni stroj, večfazni stroj, koncentrirano navitje, sintetična obremenitev, obratovanje po okvari

Projects

Funder:ARRS - Slovenian Research Agency
Project number:P2-0258
Name:Pretvorniki električne energije in regulirani pogoni

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back