izpis_h1_title_alt

Vpliv potresne izolacije na potresne zahteve armiranobetonske stavbe : diplomska naloga
ID Hassanien, Samy (Author), ID Dolšek, Matjaž (Mentor) More about this mentor... This link opens in a new window, ID Babič, Anže (Comentor)

.pdfPDF - Presentation file, Download (4,94 MB)
MD5: 5085A313DD02878B2976E0FC579654F4

Abstract
V nalogi obravnavamo potresno analizo trietažne armiranobetonske okvirne stavbe, tj. stavbe SPEAR, in potresni analizi dveh različici potresno izolirane stavbe SPEAR, pri čemer sta uporabljeni elastomerni ali trenjski potresni izolatorji. Najprej razložimo teorijo potresne izolacije konstrukcij in enačbe, ki opisujejo dinamične lastnosti potresno izolirane stavbe z modelom z dvema prostostnima stopnjama (angl. 2DOF), kar vključuje potresno izolacijo in konstrukcijo stavbe. Nato predstavimo predpise za uporabo proti-potresnih naprav v skladu z novo različico Evrokoda 8 ter uporabo novega elastičnega spektra odziva. Nadalje opišemo stavbo SPEAR in nekatere vrste potresnih izolatorjev, od katerih sta dve vrsti izolatorjev uporabljeni za potresno analizo potresno izoliranih različic stavbe SPEAR. Poleg tega analiziramo krožni frekvenci lastnega nihanja sistema 2DOF v odvisnosti od lastnosti potresnih izolatorjev z upoštevanjem zahtev Evrokoda 8. Na koncu izvedemo potresno analizo vseh različic stavbe SPEAR in izvedemo primerjavo potresnih zahtev na konstrukcijo stavbe in potresne izolatorje. Ugotovimo, da je obremenitev potresnih izolatorjev pa v mejah dovoljenih vrednosti, obremenitev konstrukcijskih elementov za različici potresno izolirane stavbe SPEAR pa precej nižja kakor pri neizolirani stavbi. Zmanjšanje obremenitve konstrukcije stavbe je posledica daljšega nihajnega časa za potresno izolirano stavbo, dodatno pa potresno obtežbo zmanjša še sipanje energije v potresnih izolatorjih. Zmanjša se tudi torzijsko nihanje stavbe. Stavba niha praktično kot togo telo, kar se ne zgodi pri osnovni stavbi SPEAR.

Language:Slovenian
Keywords:diplomske naloge, gradbeništvo, potresna izolacija, potresne zahteve, armiranobetonska stavba, stavba SPEAR, sistemi 2DOF, Evrokod 8
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Place of publishing:Ljubljana
Publisher:[S. Hassanien]
Year:2024
Number of pages:1 spletni vir (1 datoteka PDF (XIII, 56 str.))
PID:20.500.12556/RUL-162321-dd1fa0eb-d8f6-4d27-eabf-476bb595039c This link opens in a new window
UDC:624.012.45:624.042.7(043.2)
COBISS.SI-ID:208963075 This link opens in a new window
Publication date in RUL:21.09.2024
Views:49
Downloads:26
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Effect of seismic isolation on seismic demands of a reinforced concrete building
Abstract:
In this thesis, we address the seismic analysis of a three-story reinforced concrete frame building, i.e. SPEAR building, and the seismic analyses for two variants of the seismically isolated SPEAR building, where either elastomeric or frictional seismic isolators are used. First, we discuss the theory of seismic isolation of structures and the equations that describe the dynamic properties of a seismically isolated building using a two-degree-of-freedom (2DOF) model, which includes seismic isolation and the building structure. We then present the requirements for the use of anti-seismic devices in accordance with the new version of Eurocode 8 and the application of the new elastic response spectrum. Furthermore, we introduce the SPEAR building and some types of seismic isolators, two of which are used for the seismic analysis of the seismically isolated versions of the SPEAR building. Additionally, we analyze the circular frequencies for the first mode of vibration of the 2DOF system depending on the properties of the seismic isolators and considering the requirements of Eurocode 8. Finally, we conduct a seismic analysis of all variants of the SPEAR building and compare the seismic demands on the building structure. We find that the seismic demand on the seismic isolators is within the allowable limits, while the seismic demand on the structural elements for the seismically isolated versions of the SPEAR building is significantly lower compared to the non-isolated building. The reduction of seismic demand on the structure is due to the lengthening of the period of vibration, with an additional reduction in the seismic demand due to the energy dissipation in the seismic isolators. The torsional vibration of the building is also reduced. The building vibrates almost as a rigid body, which was not the case with the original SPEAR building.

Keywords:graduation thesis, civil engineering, potresna izolacija, potresne zahteve, armiranobetonska stavba, stavba SPEAR, sistemi 2DOF, Evrokod 8

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back