Abstract
The prediction of the arterial zero-stress state is as of yet an unresolved problem in the field of modelling the mechanical response of patientspecific arteries. This is because the configuration associated with arterial zero-stress state is impossible to obtain experimentally. However, the zero-stress configuration (or, equivalently, the residual stresses related to this configuration) represents the crucial data of any numerical analysis. In this study, the mechanical response of a pre-stressed, pressurised, hyperelastic tube (representing the artery) is determined without knowing the initial zero-stress configuration of the artery. Instead, to predict the arterial residual (bending and stretching) stresses, a corresponding thermomechanical analogy is used. As shown in the paper, the arterial residual stress state can equally be obtained by thermally loading a properly defined closed tube. Thus, based on the loaded state of the corresponding thermomechanical model, the arterial residual stress sate is constructed, from where the arterial loaded state can be obtained. The initial configuration of the thermomechanical model is defined on the basis of the arterial loaded configuration. The methodology is validated by predicting the zero-stress state of the artery. The predicted equilibrium state of the artery, when cut longitudinally and transversally, has the form of an opened-up tube with a relatively low stress state in comparison to the arterial residual stresses. The results thus demonstrate that arterial residual stresses that are predicted with the corresponding thermomechanical model exhibited the bending distribution, which proves the methodology to be adequate.

Language:English
Keywords:residual stresses, zero-stress state of arteries, finite element method, thermomechanics
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FS - Faculty of Mechanical Engineering
Publication status:Published
Publication version:Version of Record
Year:2015
Number of pages:Str. 5-23, SI 5
Numbering:Vol. 61, no. 1
PID:20.500.12556/RUL-160826-0f3e5925-357c-39f3-acb4-db1e2339826b This link opens in a new window
UDC:531/533+616.13(045)
ISSN on article:0039-2480
DOI:10.5545/sv-jme.2014.2061 This link opens in a new window
COBISS.SI-ID:13856795 This link opens in a new window
Publication date in RUL:05.09.2024
Views:232
Downloads:46
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Strojniški vestnik
Shortened title:Stroj. vestn.
Publisher:Zveza strojnih inženirjev in tehnikov Slovenije [etc.], = Association of Mechanical Engineers and Technicians of Slovenia [etc.
ISSN:0039-2480
COBISS.SI-ID:762116 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Title:Uporaba termomehanske analogije za določitev zaostalega napetostnega stanja arterij
Abstract:
Določitev breznapetostnega stanja arterij predstavlja še vedno nerazrešen problem na področju numeričnega modeliranja mehanskega odziva realnih arterij. Breznapetostno stanje arterije, ki ima v splošnem obliko krožnega sektorja, je namreč eksperimentalno nemogoče določiti. Oblika breznapetostnega stanja (oziroma temu pripadajoče zaostalo napetostno stanje) pa je pomembno zato, ker predstavlja začetno stanje in tako ključen podatek sleherne numerične analize. Arterije se za karakterizacijo njihovega mehanskega odziva običajno obravnava kot idealno krožne cevi, to pomeni idealno krožne in ravne. Takšna poenostavitev omogoča določitev zaostalih napetosti arterije brez poznavanja njihovega breznapetostnega stanja. Prisotnost zaostalih napetosti je posledica homogenizacije odziva arterij in vivo. Napetostno stanje arterije in vivo bi bilo namreč izrazito nehomogeno z velikim transmuralnim gradientom brez upoštevanja zaostalih napetosti. Zaradi njihove porazdelitve skozi debelino žilne stene se jih običajno asociira z upogibnimi napetostmi. Na notranji površini kolobarja so zaostale napetosti tlačne, medtem ko so na zunanji površini natezne.

Keywords:biomehanika, zaostale napetosti, breznapetostno stanje arterij, metoda končnih elementov, termomehanika