Abstract
V diplomski nalogi smo se osredotočili na analizo omočene površine pri procesu oblaganja tablete. Pripravili smo merilno progo, pri kateri smo spremljali, kako se spreminja omočenost tablete, ko na površje le-te pade najprej ena kapljica, nato pa z različnimi časovnimi zamiki še druga kapljica. Določili smo volumne kapljic za različne pretoke kapljevine, časovne zamike padca druge kapljice ter analizirali spreminjanje velikosti omočene površine ob spreminjanju teh dveh parametrov. Za večjo omočeno površino potrebujemo večji pretok, posledično velik volumen kapljice ali kratek časovni zamik padca druge kapljice. Največja omočena površina pri igli G30 je bila pri pretoku 550 µl/min, najmanjša pri pretoku 10 µl/min, pri igli G34 pa je bila največja omočena površina pri pretoku 450 µl/min, najmanjša pa pri pretoku 6 µl/min.

Language:Slovenian
Keywords:omočenje površine, oblaganje tablete, meritve, volumen kapljice
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[A. Kranjc]
Year:2023
Number of pages:XII, 45 str.
PID:20.500.12556/RUL-145762 This link opens in a new window
UDC:53.08:615(043.2)
COBISS.SI-ID:152042243 This link opens in a new window
Publication date in RUL:12.05.2023
Views:680
Downloads:130
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Effect of time delay between impacts of droplets on the wetted surface area of a tablet
Abstract:
In the diploma thesis, we focused on analyzing the wetted surface during the tablet coating process. A measuring setup was prepared comprising of a high speed camera, a strong light, a syringe pump and a computer, which was used to evaluate how the wetted areas of the tablet changes when water drops fall on its surface. Volumes for different liquid flow rates and the time delays of the drop of the second droplet were determined, and the change in the size of the wetted surface when changing these two parameters were analyzed. For a larger wetted surface a larger flow is needed, resulting in a large droplet volume or a short time delay for the second droplet to fall. The largest wetted surface for the G30 needle was at a flow rate of 550 μl/min, the smallest at a flow rate of 10 μl/min, the largest wetted area for the G34 needle was at a flow rate of 450 μl/min and the smallest at a flow rate of 6 μl/min.

Keywords:surface wetting, tablet coating, measurments, droplet volume