izpis_h1_title_alt

Potresnoodporno projektiranje 5-etažne jeklene stavbe po novem standardu Evrokod 8 : magistrsko delo št.: 232/II. GR
ID Filipčič, Eva (Author), ID Može, Primož (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (7,42 MB)
MD5: 7329AAD8F4D48C485AF37EEB940BA77F

Abstract
V magistrskem delu so predstavljene spremembe pri potresnoodpornem projektiranju konstrukcij, ki jih uvaja predlog novega standarda Evrokod 8. Novosti smo analizirali na praktičnem primeru 5-etažnega jeklenega objekta iz momentih okvirov in okvirov z ekscentričnimi povezji. Preučili smo nove definicije razredov duktilnosti, faktorjev obnašanja, faktorja občutljivosti za stavbe in kontrolo vplivov teorije drugega reda, kontrole etažnih pomikov v novih mejnih stanjih ter pravila za projektiranje jeklenih konstrukcij. Pravila iz trenutnega standarda Evrokod 8 za razred duktilnosti DCH smo primerjali s predlaganimi pravili za nova razreda duktilnosti DC2 in DC3. Potresnoodporno analizo smo izvedli za ravninske modele momentnih okvirov in okvirov z ekscentričnimi povezji z metodo z vodoravnimi silami. Za momente okvire smo izvedli tudi poenostavljeno nelinearno statično analizo. Ugotovili smo, da projektiranje momentnih okvirov po predlogu novega standarda Evrokod 8 dovoljuje nekoliko lažje in vitkejše konstrukcije z manjšimi dimenzijami elementov. Pri tem za dimenzioniranje niso več merodajni vplivi teorije drugega reda, temveč omejitve etažnih pomikov. Nasprotno, upoštevanje pravil predloga novega standarda Evrokod 8 povečuje zahteve nosilnosti in stabilnosti elementov ekscentričnega povezja. Sam postopek projektiranja ekscentričnega povezja se ne razlikuje od obstoječega. Zahteve poostruje povečanje potresnega dela obtežbe potresnega projektnega stanja. Obremenitve elementov ekscentričnih povezij v DC3 in DC2 so bile večje do te mere, da je bilo najbolj smiselno povečati število povezij in ohraniti primerljive dimenzije elementov.

Language:Slovenian
Keywords:gradbeništvo, magistrska dela, GR, Evrokod 8, potresnoodporno projektiranje, jeklo, razred duktilnosti, vpliv TDR, etažni pomiki, načrtovanje nosilnosti, plastični členek, potisna analiza
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Place of publishing:Ljubljana
Publisher:[E. Filipčič]
Year:2022
Number of pages:XVIII, 143 str.
PID:20.500.12556/RUL-141212-6456a8b7-f379-9204-6f0d-7c886a150d07 This link opens in a new window
UDC:006.44:624.014.2(043.3)
COBISS.SI-ID:131908099 This link opens in a new window
Publication date in RUL:25.09.2022
Views:1432
Downloads:191
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Design of 5-storey steel building for seismic resistance according to the new version of Eurocode 8 : master thesis no.: 232/II. GR
Abstract:
The master thesis deals with the changes in the seismic resistance design of structures introduced by the proposal of the new standard Eurocode 8. The novelties were analysed on a practical example of a 5-storey steel building stabilised with moment resisting frames and frames with eccentric bracings. The new definitions of ductility classes, behaviour factors, the interstorey drift sensitivity coefficient and the control of second order effects, the limitations of interstorey drifts in the new limit states and the specific rules for steel buildings were examined. The code requirements from the current Eurocode 8 for ductility class DCH were compared to the proposed rules for the new ductility classes DC2 and DC3. Seismic analysis was performed for planar models of moment resisting frames and frames with eccentric bracings using the lateral force method. A nonlinear static analysis (pushover) for the moment resisting frames was also performed. It was found that the design of moment resisting frames according to the proposal of the new Eurocode 8 allows somewhat lighter and slimmer structures. In this case, the influences of the second order effects are no longer governing, but rather by the limitations of interstorey drifts. On the contrary, following the changes of the new Eurocode 8 means higher resistance and stability requirements for frames with eccentric bracings. Seismic resistance design of frames with eccentric bracings does not differ from current process. The resistance and stability requirements are intensified by the increase of the seismic part of the seismic design state. The internal forces in the frame with eccentric bracings designed for DC2 and DC3 were greater to the point that it was more reasonable to increase the number of eccentric bracings and maintain comparable element dimensions.

Keywords:civil engineering, master thesis, Eurocode 8, earthquake resistance design, steel, ductility class, second order effects, interstorey drifts, capacity design, plastic hinge, pushover analysis

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back