izpis_h1_title_alt

Comparison of ADVIA Centaur ultra-sensitive and high-sensitive assays for troponin I in serum
ID Osredkar, Joško (Author), ID Fabjan, Teja (Author), ID Kumer, Kristina (Author), ID Tršan, Jure (Author), ID Poljančič, Laura (Author), ID Košir, Miha (Author), ID Vovk, Pia (Author), ID Snoj, Nada (Author), ID Finderle, Petra (Author), ID Možina, Hugon (Author)

.pdfPDF - Presentation file, Download (1,57 MB)
MD5: D7D34255E1ED79487A6313BF34F1DEF1
URLURL - Source URL, Visit https://www.sciencedirect.com/science/article/pii/S2352551722000324 This link opens in a new window

Abstract
Cardiac troponin I (cTnI) is a standard biomarker for the diagnosis of acute myocardial infarction (AMI). While older, ultra-sensitive cTnI (us-cTnI) assays use the 99th percentile as the reference threshold, newer high-sensitive cTnI (hs-cTnI) assays use the limit of detection or functional sensitivity instead. However, little has been done to systematically compare these two methods. The present study also served as a validation of hs-cTnI in our laboratory. Here, we compared the results obtained from the blood serum obtained from 8810 patients using the us-cTnI and the hs-cTnI assays run in tandem on the ADVIA Centaur XP analyser. We found that in 2279 samples the concentration of cTnI measured with the ultra-sensitive method was below the detection limit, while with the high-sensitive method, only 540 were below the detection limit. We also compared results from these assays with the ultimate diagnosis of a subset of individuals. The analysis of the results below cut-off with the ultra-sensitive method showed that this method would not detect 96 cases related to heart disorder. Overall, the main finding of our research is that hs-cTnI is the preferable option and is able to be deployed effectively in the laboratory setting.

Language:English
Keywords:acute coronary syndrome, myocardial infarction, troponin I, verification
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FFA - Faculty of Pharmacy
MF - Faculty of Medicine
Publication status:Published
Publication version:Version of Record
Year:2022
Number of pages:6 str.
Numbering:Vol. 31, art. e00293
PID:20.500.12556/RUL-139678 This link opens in a new window
UDC:616-074:616.127-005.8+616.132.2
ISSN on article:2352-5517
DOI:10.1016/j.plabm.2022.e00293 This link opens in a new window
COBISS.SI-ID:115290371 This link opens in a new window
Publication date in RUL:06.09.2022
Views:373
Downloads:76
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Practical laboratory medicine
Publisher:Elsevier
ISSN:2352-5517
COBISS.SI-ID:526495513 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:verifikacija, troponin I, miokardni infarkt, akutni koronarni sindrom, klinična kemija

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back