izpis_h1_title_alt

A dynamic calibration of optical fiber DTS measurements using PEST and reference thermometers
ID Ghafoori, Yaser (Author), ID Vidmar, Andrej (Author), ID Kryžanowski, Andrej (Author)

.pdfPDF - Presentation file, Download (3,96 MB)
MD5: BC245E4222553CF5B001C7AAB7DA39F5
URLURL - Source URL, Visit https://www.mdpi.com/1424-8220/22/10/3890 This link opens in a new window

Abstract
Temperature measurements are widely used in structural health monitoring. Optical fiber distributed temperature sensors (DTS) are developed, based on Raman spectroscopy, to measure temperature with relatively high accuracy and short temporal and spatial resolutions. DTS systems provide an extensive number of temperature measurements along the entire length of an optical fiber that can be extended to tens of kilometers. The efficiency of the temperature measurement strongly depends on the calibration of the DTS data. Although DTS systems internally calibrate the data, manual calibration techniques were developed to achieve more accurate results. Manual calibration employs reference sections or points with known temperatures and the DTS scattering data to estimate the calibration parameters and calculate temperature along the optical fiber. In some applications, manual calibration is subjected to some shortages, based on the proposed fiber installation configuration and continuity of calibration. In this article, the manual calibration approach was developed using the model-independent Parameters Estimation (PEST), together with the external temperature sensors as references for the DTS system. The proposed method improved manual calibration in terms of installation configuration, continuity of dynamic calibration, and estimation of the calibration parameters.

Language:English
Keywords:optical fiber DTS, calibration, PEST, thermometer, Raman scattering, temperature
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FGG - Faculty of Civil and Geodetic Engineering
Publication status:Published
Publication version:Version of Record
Year:2022
Number of pages:13 str.
Numbering:Vol. 22, iss. 10, art. 3890
PID:20.500.12556/RUL-138521 This link opens in a new window
UDC:556:626/627
ISSN on article:1424-8220
DOI:10.3390/s22103890 This link opens in a new window
COBISS.SI-ID:115181827 This link opens in a new window
Publication date in RUL:25.07.2022
Views:424
Downloads:44
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Sensors
Shortened title:Sensors
Publisher:MDPI
ISSN:1424-8220
COBISS.SI-ID:10176278 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Keywords:optična vlakna DTS, kalibracija, PEST, termometer, Ramanovo sipanje, temperatura

Projects

Funder:ARRS - Slovenian Research Agency
Project number:P2-0180
Name:Vodarstvo in geotehnika: orodja in metode za analize in simulacije procesov ter razvoj tehnologij

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back