izpis_h1_title_alt

Merjenje globalne deformacije prenosnikov toplote
ID Gabrovšek, Simon (Author), ID Kutin, Jože (Mentor) More about this mentor... This link opens in a new window, ID Svete, Andrej (Comentor)

.pdfPDF - Presentation file, Download (6,08 MB)
MD5: 2B66F9C073478DCD3DE3EEC1297055E2

Abstract
Lotani prenosniki toplote morajo izpolnjevati različne varnostne zahteve, kot je dopustni tlak porušitve. Za točno določanje dopustnega tlaka in čim manjše varnostne faktorje, moramo čim bolj poznati spremembe, ki se dogajajo na prenosniku toplote med tlačno obremenitvijo. Spremembe popisuje globalna deformacija prenosnika toplote. V ta namen smo zasnovali merilno progo, kjer merimo spremembo volumna s pomočjo merilnika tlačne razlike in vertikalnih merilnih ceveh. Sistem je zasnovan tako, da prenosnik toplote v celoti napolnimo z vodo in potopimo v vodo v posodi. Na zunanji strani imamo nameščene vertikalne merilne cevi, v katerih s pomočjo merilnika tlačne razlike merimo višino vodnega stolpca v cevi. V drugem delu smo izvedli kalibracijo merilnih cevi in ovrednotili najpomembnejše zunanje vplive. Med kalibracijo se je izkazalo, da je dejanski premer vertikalnih merilnih cevi od 2 do 3,04 % večji od teoretičnega. Največji zunanji vpliv predstavlja raztezanje posode. V primeru najmanjše merilne cevi premera 4 mm ta lahko znaša več kot tretjino merilnega območja. Rezultati kažejo, da lahko vpliv segrevanja vode zanemarimo, če je merilni postopek ustrezen. Upoštevati je potrebno še raztezanje hidravličnih cevi, ko so obremenjene s tlakom. Na osnovi rezultatov meritev smo definirali tudi ustrezen postopek odzračevanja prenosnikov toplote na način, da zmanjšamo vpliv zračnih mehurčkov, ki lahko ostanejo ujeti v prenosniku. Za konec smo izvedli še meritve na vzorcih prenosnikov toplote, za katere smo določili volumsko deformacijo v odvisnosti od tlačne obremenitve.

Language:Slovenian
Keywords:lotani prenosnik toplote, globalna deformacija, merilna metoda, zunanji vplivi, merjenje, volumska deformacija
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[S. Gabrovšek]
Year:2022
Number of pages:XXIV, 72 str.
PID:20.500.12556/RUL-137604 This link opens in a new window
UDC:536.24:534.61(043.2)
COBISS.SI-ID:114861827 This link opens in a new window
Publication date in RUL:23.06.2022
Views:780
Downloads:106
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Measurements of global deformation of heat exchangers
Abstract:
Brazed plate heat exchangers must meet various safety requirements, such as the permisseble burst pressure. To accurately determine the allowable pressure and minimize safety factors, we need to know as well as possible the changes, that occur on the heat exchanger during the pressure load. The changes are represented by the global deformation of the heat exchangers. For this purpos, we design a measuring line where we measure the change in volume, using a pressure difference meter and vertical measuring pipes. The system in design so that the heat exchanger is completely filled with water and immerst in the vessel which is full of water. On the outside we have installed vertical measuring pipes in which we measure the height of the water column in the pipe with the help of a pressure difference meter. In the second part, we calibrated the measuring pipes and evaluated the most important external infuences. During the calibration, actual diameter of the vertical measuring pipes turned out to be 2 % to 3,04 % larger than the theoretical one. The greatest external infuences is the expansion of vessel, in the case of a measuring pipes with a diameter of 4 mm at the maximum measured value, can be more than a third of the measuring range. The results show that the effect of water heating can be neglected if the preparation process in appropriate. However, the expansion of the hydraulic hoses when they are subjected to pressure must also be taken into account. With the help of measurements, we also defined an appropriate procedure for venting heat exchangers, in way that reduces the impact of air bubbles that may remain trapped in the heat exchanger to a negligible value. Finally, we performed measurements on samples, for which we determined the volume deformation depending on the compressive load.

Keywords:brazed plate heat exchangers, global deformation, measurement method, external in influences, measurements, volume deformation