izpis_h1_title_alt

Palm temperature differences after static and dynamic load on high bar
ID Šibanc, Karmen (Author), ID Čuk, Ivan (Author), ID Pajek, Maja (Author), ID Pušnik, Igor (Author)

.pdfPDF - Presentation file, Download (2,08 MB)
MD5: A10741F952BD526A3F78256DA5773FAB
URLURL - Source URL, Visit https://www.mdpi.com/1424-8220/21/13/4497 This link opens in a new window

Abstract
Thermal imaging is used in various fields of industry and research to measure temperature and its possible differences. Since there is a lack of research and literature on palm temperatures and prevention of blisters on hands, our question was how palm temperature differs in human hands after different loads (Hang and Swing in Hang) for 30 s on a high bar. Thirty-eight students from the Faculty of Sport at the University of Ljubljana were measured with a high-quality thermal imaging camera. Palm temperatures were measured before the load was applied, immediately after and every 30 s for a period of 5 min after the load. Each hand was divided into nine different regions of interest (ROIs). Mean (XA), standard deviation (SD), maximum and minimum, and number of pixels were calculated. We found that there was no difference between the left and right hand. The temperature right after the load was applied decreased significantly for both loads and then increased above the level before the load was applied. After the static load, the temperature reached a constant higher level after 3 min. After the dynamic load, the temperatures continued to increase throughout the measurement period. Further investigation is needed to determine the time period in which the hand temperature reaches the temperature before the load is applied.

Language:English
Keywords:palm temperature, thermal imaging, hang, swing in hang
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FŠ - Faculty of Sport
FE - Faculty of Electrical Engineering
Publication status:Published
Publication version:Version of Record
Year:2021
Number of pages:13 str.
Numbering:Vol. 21, iss. 13, art. 4497
PID:20.500.12556/RUL-135893 This link opens in a new window
UDC:621.317:796.4
ISSN on article:1424-8220
DOI:10.3390/s21134497 This link opens in a new window
COBISS.SI-ID:68796675 This link opens in a new window
Publication date in RUL:31.03.2022
Views:525
Downloads:99
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Sensors
Shortened title:Sensors
Publisher:MDPI
ISSN:1424-8220
COBISS.SI-ID:10176278 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.
Licensing start date:01.07.2021

Secondary language

Language:Slovenian
Keywords:temperatura dlani, termovizija, vesa, koleb

Projects

Funder:ARRS - Slovenian Research Agency
Project number:P2-0225
Name:Metrologija in kakovost

Funder:ARRS - Slovenian Research Agency
Project number:P5-0147
Name:Kineziologija monostrukturnih, polistrukturnih in konvencionalnih športov

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back