izpis_h1_title_alt

Simultaneous hand–eye and intrinsic calibration of a laser profilometer mounted on a robot arm
ID Pavlovčič, Urban (Author), ID Arko, Peter (Author), ID Jezeršek, Matija (Author)

.pdfPDF - Presentation file, Download (18,78 MB)
MD5: 220A242A9E0DD5F80D19C54F10EE209B
URLURL - Source URL, Visit https://www.mdpi.com/1424-8220/21/4/1037 This link opens in a new window

Abstract
A method for simultaneous laser profilometer and hand-eye calibration in relation to an industrial robot as well as its implementation is presented. In contrast to other methods, the new calibration procedure requires the measurement of only one reference geometry to calculate all the transformation parameters. The reference geometry is measured with a laser profilometer from 15 different poses. The intrinsic parameters of the profilometer, as well as the extrinsic (hand–eye) parameters, are then numerically optimized to achieve the minimum deviation between the reference and the measured geometry. The method was characterized with experiments that revealed a standard deviation of the displacements between the reference geometry after the calibration of less than 0.105 mm in the case of using the robot-arm actuator and 0.046 mm in case of using a 5-axis CNC milling machine. The entire procedure, including measurement and calculation, can be completely automated and lasts less than 10 min. This opens up possibilities for regular on-site recalibration of the entire system.

Language:English
Keywords:3D-scanner calibration, laser scanning, hand-eye calibration, laser triangulation profilometer, robotic vision
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FS - Faculty of Mechanical Engineering
Publication status:Published
Publication version:Version of Record
Year:2021
Number of pages:23 str.
Numbering:Vol. 21, iss. 4, art. 1037
PID:20.500.12556/RUL-134961 This link opens in a new window
UDC:004.946:681.518.52(045)
ISSN on article:1424-8220
DOI:10.3390/s21041037 This link opens in a new window
COBISS.SI-ID:51371011 This link opens in a new window
Publication date in RUL:14.02.2022
Views:1008
Downloads:139
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Record is a part of a journal

Title:Sensors
Shortened title:Sensors
Publisher:MDPI
ISSN:1424-8220
COBISS.SI-ID:10176278 This link opens in a new window

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.
Licensing start date:03.02.2021

Secondary language

Language:Slovenian
Keywords:kalibracija 3D merilnika, lasersko skeniranje, laserski triangulacijski profilomer, strojni vid

Projects

Funder:Other - Other funder or multiple funders
Funding programme:Slovenia
Project number:C3330-16-529000
Acronym:GOSTOP

Funder:EC - European Commission
Funding programme:ERDF
Acronym:GOSTOP

Funder:ARRS - Slovenian Research Agency
Project number:P2-0392
Name:Optodinamika

Funder:ARRS - Slovenian Research Agency
Project number:L2-8183
Name:Visoko prilagodljivi vlakenski laserji velikih moči za uporabo v industriji

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back