T1 in T2 mapiranje pri magnetno resonančnem slikanju srca : magistrsko delo
ID Šubej, Laura (Author), ID Mekiš, Nejc (Mentor) More about this mentor... This link opens in a new window, ID Breznik, Andrej (Comentor), ID Šantl-Letonja, Marija (Reviewer)

.pdfPDF - Presentation file, Download (1,36 MB)
MD5: 67FCBA5807D44F88B9C6046E0EF7D423

Abstract
Uvod: Magnetno resonančno slikanje srca se danes širom sveta uporablja na področju povezanim s srčno žilnimi boleznimi. Največja prednost magnetno resonančnega slikanja srca je tridimenzionalen prikaz struktur z odlično prostorsko in visoko kontrastno ločljivostjo. Z njo se omogoča merjenje srčne funkcije in oceno morfoloških struktur. Napredek tehnologije je omogočil slikanje s T1 in T2 mapiranjem. Namen: Ugotoviti kakšne so nativne vrednosti T1 in T2 mapiranja pri zdravih preiskovancih ter ugotoviti vpliv preiskovalnega polja na vrednosti T1 in T2 relaksacijskega časa pri izvajanju T1 in T2 mapiranja. Metode dela: V raziskavo je bilo vključenih 30 zdravih prostovoljcev. Raziskava je potekala na MR aparatu znamke Siemens Magnetom Aera 1,5 T. Nihče izmed prostovoljcev ni imel predhodno zabeležene znane srčno-žilne bolezni ali rizičnih dejavnikov. Vsakemu prostovoljcu smo opravili nativno T1 in T2 mapiranje srčne mišice pri različnih velikostih slikovnega polja. Izvedli smo korekcijo velikosti FOV-a in sicer tako, da smo velikost povečevali za 10 mm, in sicer od 360 mm di 390 mm. V drugem delu raziskave pa smo v računalniški program vrisovali interesna področja v interventrikularni septum ter zabeležili meritve. Rezultati: Primerjava med velikosti slikovnega polja pri T1 mapiranju je pokazala, da obstajajo minimalne statistične razlike v vrednosti T1 relaksacijskih časov. Vse izmerjene in izračunane vrednosti so v okvirih referenčnih vrednosti T1 relaksacijskih časov. Primerjava med velikosti slikovnega polja pri T2 mapiranju je pokazala, da ne obstajajo statistično značilne razlike v vrednosti T2 relaksacijskih časov. Vse izmerjene in izračunane vrednosti so v okvirnih referenčnih vrednosti T2 relaksacijskih časov. Tekom raziskave smo ugotovili, da obstajajo razlike med spoloma tako pri T1 kot pri T2 mapiranju. Razprava in zaključek: Ugotovili smo, da so povprečne nativne vrednosti T1 in T2 mapiranja primerljive z rezultati drugih raziskav ter da jih lahko primerjamo z nativnimi referenčnimi vrednostmi zdravega miokarda. V drugem delu raziskave smo raziskovali ali velikost slikovnega polja vpliva na izmerjene vrednosti T1 in T2 mapiranje pri MR slikanju srca. Ugotovili smo, da obstajajo posamezne minimalne razlike med izračunanimi vrednostmi T1 in T2 relaksacijskih časov, vendar so izmerjene vrednosti še vedno v okviru normalnih vrednosti.

Language:Slovenian
Keywords:magistrska dela, radiološka tehnologija, MR slikanje srca, T1 mapiranje, T2 mapiranje
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:ZF - Faculty of Health Sciences
Place of publishing:Ljubljana
Publisher:[L. Šubej]
Year:2021
Number of pages:63 str.
PID:20.500.12556/RUL-131571 This link opens in a new window
UDC:616-07
COBISS.SI-ID:79062531 This link opens in a new window
Publication date in RUL:29.09.2021
Views:1154
Downloads:135
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:T1 and T2 mapping in cardiac magnetic resonance : master thesis
Abstract:
Introduction: Magnetic resonance imaging of the heart is used worldwide today in the field related to cardiovascular disease. The biggest advantage of magnetic resonance imaging of the heart is the three-dimensional display of structures with excellent spatial and high contrast resolution. It enables the measurement of cardiac function and the assessment of morphological structures. Advances in technology have made imaging possible with T1 and T2 mapping. Purpose: To determine the native values of T1 and T2 mapping in healthy subjects and to determine the influence of the test field on the values of T1 and T2 relaxation time when performing T1 and T2 mapping. Methods: 30 healthy volunteers were included in the study. The study was performed on a Siemens Magnetom Aera 1.5 T MR. None of the volunteers had a known history of known cardiovascular disease or risk factors. For each volunteer, we performed native T1 and T2 mapping of the heart muscle at different image field sizes. We performed a size correction of the FOV by increasing the size by 10 mm, from 360 mm to 390 mm. In the second part of the research, we plotted areas of interest in the interventricular septum in a computer program and recorded measurements. Results: A comparison between image field sizes in T1 mapping showed that there are minimal statistical differences in the values of T1 relaxation times. All measured and calculated values are within the reference values of T1 relaxation times. A comparison between the image field sizes in T2 mapping showed that there are no statistically significant differences in the values of T2 relaxation times. All measured and calculated values are in the approximate reference values T2 of relaxation times. During the research, we found that there are gender differences in both T1 and T2 mapping. Discussion and conclusion: We found that the average native values of T1 and T2 mapping are comparable with the results of other studies and that they can be compared with the native reference values of a healthy myocardium. In the second part of the study, we investigated whether the size of the image field affects the measured values of T1 and T2 mapping in MR imaging of the heart. We found that there are individual minimal differences between the calculated values of T1 and T2 relaxation times, but the measured values are still within normal values.

Keywords:master's theses, radiologic technology, MR imaging of heart, T1 mapping, T2 mapping