izpis_h1_title_alt

Določanje aldehidov v notranjih prostorih s pasivnimi vzorčevalniki
ID Magaš, Tilen (Author), ID Kralj Cigić, Irena (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (1,82 MB)
MD5: B17E62A5CBD33F19DADB7559DA6617C7

Abstract
V svoji diplomski nalogi sem določal aldehide v notranjih prostorih na Fakulteti za kemijo in kemijsko tehnologijo Univerze v Ljubljani. Aldehide sem določal na štirih vzorčevalnih mestih in sicer v zaprti knjižni omari, v pisarni, na hodniku in v laboratoriju. Primerjal sem dve vrsti vzorčevalnikov in sicer komercialne in laboratorijsko pripravljene. Komercialni so originalni lističi za UMEx 100 vzorčevalnike, laboratorijsko pa sem pripravil lističe impregnirane s kislo DNPH raztopino, ki sem jih nato vstavil v prazna ohišja UMEx vzorčevalnikov. Aldehidi so se na impregniranih lističih derivatizirali, derivate sem eluiral in nato izvedel ločbo. Za ločevanje in določanje derivatov iz vzorčevalnikov sem uporabil HPLC kromatografsko tehniko z metodo umeritvenih premic. Izračunal sem koncentracije posameznih aldehidov v določenem prostoru, relativne standardne odmike in meje zaznave za posamezen analit in za obe vrsti vzorčevalnikov. Ugotovil sem, da je koncentracija aldehidov najvišja v knjižni omari, najnižja pa v laboratoriju. Ugotovil sem tudi, da so za oba vzorčevalnika, primerljive meje zaznave. Koncentracije posameznih aldehidov niso na nobenem vzorčevalnem mestu presegle mejnih vrednosti v zraku.

Language:Slovenian
Keywords:aldehidi, derivatizacija, HPLC, UMEx 100
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Technology
Year:2021
PID:20.500.12556/RUL-129938 This link opens in a new window
COBISS.SI-ID:81918723 This link opens in a new window
Publication date in RUL:09.09.2021
Views:1435
Downloads:54
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Determination of aldehydes indoors using passive samplers
Abstract:
In my diploma thesis, I determined aldehydes indoors at the Faculty of Chemistry and Chemical Technology, University of Ljubljana. I determined aldehydes at four sampling locations; in the bookshelf, in the office, in the hallway, and in the laboratory. I compared two types of samplers; commercially avalible and laboratory – prepared. The commercial samplers are original tapes for UMEx 100 samplers, while the laboratory – prepared tapes are impregnated with an acidic DNPH solution which was placed into the empty UMEx sampler housing. The aldehydes were derivatized on the impregnated tapes, the derivatives were eluted and then separated. I used HPLC chromatographic technique to separate and determine the components from the samplers using the calibration line method. I calculated the concentrations of individual aldehydes at each sampling location, the relative standard deviations, and the limits of detection for each analyte and for both types of samplers. I found that the concentration of aldehydes is highest in the bookshelf and lowest in the laboratory. I also found that the both samplers had comparable limits of detection. The concentrations of individual aldehydes did not exceed the limit values in the air at any sampling location.

Keywords:aldehyde, derivatization, HPLC, UMEx 100