izpis_h1_title_alt

Analiza izvornih vzrokov puščanja na membranskih pogonih regulatorskih ventilov
ID Laščak, Jure (Author), ID Kos, Leon (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (3,35 MB)
MD5: 9DDA6445869E87FC96753F0264F900D8

Abstract
V diplomski nalogi je na sistemski način prikazano reševanje problema puščanja membranskih pogonov regulatorskih ventilov. Po korakih procesa 8D in z uporabo orodij za iskanje izvornega vzroka problema je izvedena analiza izdelka, orodij, materiala in procesa. Ugotovljena so odstopanja meritev materiala od zahtevanih vrednosti, obraba in ovalna oblika orodja za preoblikovanje pa tudi napačno zasnovan utor za o-tesnilo. Z novo zasnovo utora, novim orodjem ter materialom, je izmet zmanjšan na željeno vrednost, ki je manj kot 1 %. Vse izboljšave smo potrdili s proizvodnimi in tlačnim testom.

Language:Slovenian
Keywords:puščanje, stiskanje, o-tesnilo, proces 8D, tlačni test
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[J. Laščak]
Year:2021
Number of pages:XXII, 51 str.
PID:20.500.12556/RUL-127959 This link opens in a new window
UDC:62-762.84:621.643.8(043.2)
COBISS.SI-ID:70838787 This link opens in a new window
Publication date in RUL:30.06.2021
Views:615
Downloads:114
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Root cause analysis of leakage on membrane valve drives
Abstract:
The diploma thesis present the solution for the problem of leaking diaphragm actuators of control valves on systematic way. Over the steps of 8D process and using different tools for problem solving to find root cause of the problem, an analysis of the product, tools, material and process is performed. Deviation of material dimensions from the required values, wear and oval shape of forming tool and incorrectly designed o-ring seal groove, has been identified. With the new groove design, new tools and material the scrap is reduced to the desired value of less than 1 %. All improvments was have been validated by production and burst tests.

Keywords:leaking, compression, o-ring, proces 8D, burst test