izpis_h1_title_alt

Dinamske obremenitve vijačnih vzmeti
ID Bregar, Luka (Author), ID Slavič, Janko (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (36,88 MB)
MD5: EB108077B1294ECC1C64D1CBDFDCBE83

Abstract
Vijačne vzmeti se v hitrotekočih vratih uporablja kot akumulator mehanske energije, ki pripomore k hitremu odpiranju vratne plošče. Zaradi hitrega odpiranja in sunkovitih pomikov vzmeti nihajo, kar lahko vpliva na njihovo dobo trajanja. S pomočjo metode dinamske togosti so bile določene lastne frekvence obravnavane vzmeti. Sledila je določitev kritično obremenjenih mest na podlagi implicitne in harmonske analize. Z modificiranim Goodmanovim diagramom in Bergmannovo korekcijo je bila ocenjena doba trajanja za kritično obremenjena mesta na vzmeti. Rezultati so bili eksperimentalno preverjeni. Ugotovljeno je bilo, da odziv z lastnimi oblikami privede do višjih napetosti in krajše dobe trajanja v primerjavi s kvazi-statično obremenitvijo.

Language:Slovenian
Keywords:vijačne vzmeti, dinamske obremenitve, dinamska togost, implicitna analiza, harmonska analiza, modificiran Goodmanov diagram, Bergmannova korekcija
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[L. Bregar]
Year:2021
Number of pages:XXVIII, 79 str.
PID:20.500.12556/RUL-125611 This link opens in a new window
UDC:621.826.22:531.3:620.172(043.2)
COBISS.SI-ID:58578947 This link opens in a new window
Publication date in RUL:27.03.2021
Views:737
Downloads:206
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Dynamic loads of helical springs
Abstract:
Coil springs are used in high-speed doors as a mechanical energy accumulator, which contributes to a rapid opening of the door leaf. Due to the rapid opening and jerky movements, the springs oscillate, which can reduce their service life. Using the dynamic stiffness formulation, the natural frequencies of the considered spring were determined. This was followed by the identification of critically loaded points based on implicit and harmonic analysis. With a modified Goodman diagram and Bergmann correction, service life of critical points on the spring was estimated. The results were experimentally verified. It has been found that the response with natural frequency modes leads to higher stresses and shorter service life, if compared to the quasi-static case.

Keywords:coil springs, dynamic loads, dynamic stiffness formulation, implicit analysis, harmonic analysis, modified Goodman diagram, Bergmann correction