izpis_h1_title_alt

Zanesljivost in veljavnost enostavnih kliničnih merilnih orodij in testov za ocenjevanje odstopanj drže pri adolescentni idiopatski skoliozi : diplomsko delo
ID Blatnik, Jure (Author), ID Hlebš, Sonja (Mentor) More about this mentor... This link opens in a new window, ID Jakovljević, Miroljub (Reviewer)

.pdfPDF - Presentation file, Download (783,34 KB)
MD5: 42114391D6A44DB7162382C14AEB4330

Abstract
Uvod: Adolescentna idiopatska skolioza je tridimenzionalna deformacija hrbtenice in trupa ter je najpogostejša oblika skolioze. Diagnoza je izločilna in je postavljena, kadar je Cobbov kot enak ali večji od 10° in je hkrati opazna osna rotacija trupa. Za zgodnje ugotavljanje se izvaja presejalne programe, pri katerih uporabljajo različne klinične postopke za ocenjevanje odstopanj drže, vendar njihova učinkovitost še ni dobro raziskana. Namen: Na podlagi pregleda literature predstaviti zanesljivost in veljavnost poceni in enostavnih kliničnih testov in merilnih orodij za ocenjevanje odstopanj drže pri preiskovancih z adolescentno idiopatsko skoliozo. Metode dela: V podatkovnih zbirkah PubMed smo poiskali literaturo, ki je bila objavljena med letoma 2009 in 2020. S pomočjo vključitvenih in izključitvenih kriterijev je bilo izbranih devet raziskav. Rezultati: Rezultati pregledanih raziskav so pokazali zelo dobro do odlično zanesljivost in dobro veljavnost skoliometra. Aplikacija Scoligauge se je izkazala z odlično zanesljivostjo in veljavnostjo, inklinometer Baseline / skoliometer je imel zelo dobro zanesljivost, vendar zmerno veljavnost. Zanesljivost testa predklona in lestvice Estetske klinične ocene trupa je bila slaba. Razprava in zaključek: Pregled literature je pokazal, da so si avtorji raziskav neenotni glede zanesljivosti TRACE lestvice in testa predklona, medtem ko je zanesljivost in veljavnost ostalih kliničnih testov in merilnih orodij klinično pomembna. Klinični testi ali merilna orodja za ocenjevanje odstopanj drže morajo biti enostavni, poceni, hitri in zanesljivi, da se izognemo večkratni izpostavitvi rentgenskemu sevanju. V naslednjih raziskavah bi bilo potrebno vključiti več preiskovalnih in kontrolnih skupin ter standardizirati izvedbe testov in postopke merjenja.

Language:Slovenian
Keywords:diplomska dela, fizioterapija, adolescentna idiopatska skolioza, skoliometer, Scoliogauge, Baseline body level/scoliosis meter, TRACE, klinične metode
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:ZF - Faculty of Health Sciences
Place of publishing:Ljubljana
Publisher:[J. Blatnik]
Year:2021
Number of pages:33 str.
PID:20.500.12556/RUL-125577 This link opens in a new window
UDC:615.8
COBISS.SI-ID:57316611 This link opens in a new window
Publication date in RUL:26.03.2021
Views:1850
Downloads:155
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Reliability and validity of easily administered clinical evaluation methods of postural asymmetry measurement in adolescent idiopathic scoliosis : diploma work
Abstract:
Introduction: Adolescent idiopathic scoliosis is a three-dimensional deformity of spine and trunk and is the most common form of scoliosis. The diagnosis is excretory and is made when the Cobb angle is equal to or greater than 10° and axial trunk rotation is simultaneously observed. School-based screening programs are used to identify adolescent idiopathic scoliosis using various clinical assessment methods to evaluate deformity, but their effectiveness has not been well studied. Purpose: The aim of the thesis was to present the reliability and validity of low-cost and easy-to-perform clinical assessment methods for the evaluation of postural asymmetry in adolescent idiopathic scoliosis. Methods: English-language literature published between 2009 and 2020 was searched in PubMed. Nine studies were selected considering inclusion and exclusion criteria. Results: The results of the studies reviewed indicate very good to excellent reliability of the scoliometer, which has good validity. The Scoligauge app showed excellent reliability and validity, Baseline Body Level / Scoliosis Metre was highly reliable but moderately valid. The reliability of the Adam's forward test and the Trunk aesthetic clinical evaluation scale was poor. Discussion and conclusion: The literature review shows that the authors disagree on the reliability of the Trunk aesthetic clinical evaluation scale and the Adam's forward bend test, while the reliability and validity of other clinical tests and measurement tools were clinically important. Clinical assessment methods for evaluating postural abnormalities should be simple, inexpensive, rapid, and reliable to avoid repeated exposure to X-rays. Further research should include more study and control groups and compare results between them and standardize measurement protocols.

Keywords:diploma theses, physiotherapy, adolescent idiopathic scoliosis, scoliometer, Scoliogauge, Baseline body level/scoliosis meter, Trunk aesthetic clinical evaluation, clinical methods

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back