izpis_h1_title_alt

Okrevanje silicijevih fotopomnoževalk po obsevanju z nevtroni
ID Zajc, Gašper (Author), ID Pestotnik, Rok (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (13,62 MB)
MD5: DB27D4EFDDB0C3D468F5776022BE02BF

Abstract
Silicijeve fotopomnoževalke so polprevodniški detektorji svetlobe, sposobni zaznavati posamezne fotone. Sestavljene so iz mreže plazovnih fotodiod. So veliko manjše od običajnih fotopomnoževalk, neobčutljive na magnetno polje, imajo nižjo ceno izdelave ter delujejo pri manjših napetostih. Silicijeve fotopomnoževalke si želimo uporabljati tudi v sevalnih okoljih, kot so eksperimenti v fiziki visokih energij. Na področju vpliva sevalnih poškodb na detekcijo posameznih fotonov s silicijevimi fotopomnoževalkami še ni bilo narejenih veliko študij. V tej magistrski nalogi sem raziskoval vpliv obsevanja silicijevih fotopomnoževalk z nevtroni ter vpliv segrevanja silicijevih fotopomnoževalk na odpravo sevalnih poškodb. Raziskoval sem vpliv obsevanja na napetost praga ter na sposobnost zaznave posameznega fotona. Po obsevanju smo vsako celico segrevali pet zaporednih tednov pri temperaturi 100 °C ter po vsakem tednu spremljali njihovo okrevanje.

Language:Slovenian
Keywords:silicijeve fotopomnoževalke, sevalne poškodbe, nevtroni, okrevanje
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FMF - Faculty of Mathematics and Physics
Year:2020
PID:20.500.12556/RUL-122110 This link opens in a new window
COBISS.SI-ID:49257987 This link opens in a new window
Publication date in RUL:22.11.2020
Views:830
Downloads:94
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Silicon photomultipliers recovery after neutron irradiation
Abstract:
Silicon photomultipliers are semiconductor light detectors, capable of detecting single photons. They are made of a matrix of single-photon avalanche diodes connected in parallel. They are a lot smaller than normal photomultiplier tubes, insensitive to magnetic field, have lower production prices and can be operated at lower voltages. There is a tendency for silicon photomultipliers to be used in radiation environments such as high energy physics experiments. In the field of the influence of radiation damage on the detection of individual photons with silicon photomultipliers, not many studies have been done yet. In this masters thesis, I investigated the influence of irradiation of silicon photomultipliers with neutrons and the influence of heating silicon photomultipliers on the elimination of radiation damage. I investigated the effect of radiation on the breakdown voltage and on the bility to detect an individual photon. After irradiation, each cell was heated at 100 °C for five consecutive weeks and monitored the recovery of silicon photomultipliers after each week.

Keywords:silicon photomultipliers, radiation damage, neutrons, thermal annealing