Vpliv dimenzij in materiala merjenca na občutljivost MC senzorjev
ID Žumer, Jan (Author), ID Kunc, Robert (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (2,60 MB)
MD5: 9047DC8091C96A7DECAFBE52A6B3CCDC

Abstract
Pri raziskavah, ki so se ukvarjale z uporabo MC senzorjev za merjenje obremenitve človeških mišic, se je večkrat pojavilo vprašanje vpliva različnih karakteristik merjencev na rezultate meritev. Poznavanje vpliva različnih merjencev bi dodalo vrednost in razširilo možnost uporabe senzorja. Za raziskavo smo uporabili poenostavljen model mišice, ki smo ga kontrolirano raztegovali ter na njem hkrati spremljali izmerjene vrednosti MC senzorja in vzdolžno obremenitev raztega. Potrdili smo zelo visoko linearno korelacijo izmerjenih vrednosti in v drugem delu analize ugotovili blag vpliv različnega materiala merjenca.

Language:Slovenian
Keywords:MC senzor, biomehanika, EMG elektromiografija, simulacija mišice, piezoresistivni senzorji, krčenje mišic, mišična napetost
Work type:Final paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[J. Žumer]
Year:2020
Number of pages:XIII, 27 f.
PID:20.500.12556/RUL-122086 This link opens in a new window
UDC:681.586:531:612.74(043.2)
COBISS.SI-ID:39378179 This link opens in a new window
Publication date in RUL:20.11.2020
Views:697
Downloads:83
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:The influence of dimensions and material of the specimen on the sensitivity of MC sensors
Abstract:
Past studies that used the MC sensor for measuring muscle load left unanswered the questions of the influence of different characteristics of measured human tissue. Knowing more about the influence of measured materials could add value and widen the field of research with the MC sensor. For our research, we used a simplified model of the muscle, which was dynamically stretched in a controlled manner while simultaneously measuring the actual longitudinal force and MC sensor load. We confirmed very strong linear correlation between the two values and in the second part of analysis found small influence of different measured materials.

Keywords:MC sensor, biomechanics, EMG electromyography, muscle simulation, piezoresistive sensors, muscle contraction, muscle tension