Kontrola prekrmiljenja elektromagnetnega aktuatorja na podlagi meritve električnega toka med vklopom in izklopom
ID Žust, Peter (Author), ID Majdič, Franc (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (8,08 MB)
MD5: 7EB0BAF3BD186FB91339BFAB540ED4AA

Abstract
Cilj magistrske naloge je bil najti način za kontrolo prekrmiljenja konvencionalnega hidravličnega potnega ventila, krmiljenega z elektromagnetnimi aktuatorji, na podlagi meritve električnega toka med vklopom in izklopom elektromagnetnega aktuatorja. V okviru naloge smo predstavili metodo, ki temelji na izračunu magnetnega pretoka iz izmerjenega električnega toka. Metodo smo eksperimentalno in numerično preverili. Na podlagi izbrane metode smo izdelali napravo za kontrolo prekrmiljenja ventila. Napravo smo testirali in ugotovili, da je primerna za uporabo pri serijskem testiranju konvencionalnih potnih ventilov.

Language:Slovenian
Keywords:elektromagnetni aktuator, električni tok, kotva, magnetni pretok, p-Q karakteristika, prekrmiljenje
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[P. Žust]
Year:2020
Number of pages:XXVI, 90 str., [18] str. pril.
PID:20.500.12556/RUL-121803 This link opens in a new window
UDC:621.31:681.587(043.2)
COBISS.SI-ID:39111427 This link opens in a new window
Publication date in RUL:30.10.2020
Views:1473
Downloads:45
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Switching control of a solenoid actuator based on electrical current measurement during power on and power off
Abstract:
The aim of this master’s thesis was to find a suitable solution for the switching control of a solenoid-operated hydraulic directional control valve based on measurement of the electric current during excitation and de-excitation of the actuator. In this thesis we present a method based on the calculation of the magnetic flux from the measured electric current. The method was tested experimentally and numerically. Based on the proposed method, a device for switching control of the valve was built. The device was tested and found to be suitable for series testing of directional control valves.

Keywords:solenoid actuator, electric current, armature, magnetic flux, p-Q characteristic, switching