Abstract
V magistrski nalogi smo opravili revizijo prvotno dobljene projektne dokumentacije strojnih inštalacij poslovne stavbe in jo primerjali z alternativnimi rešitvami. Projektno dokumentacijo za poslovni objekt smo preučili, jo kritično presodili in podali ustrezne optimalne popravke. Podani so bili ustrezni popravki za zagotavljanje hidravličnega uravnovešenja, kakovosti notranjega okolja, kakovosti zraka in optimalne porabe energije za potrebe ogrevanja, hlajenja in prezračevanja. S popravki smo izboljšali delovanje sistema, počutje osebja na delovnih mestih in zmanjšali porabo električne energije.

Language:Slovenian
Keywords:ogrevanje, hlajenje, klimatizacija hidravlično uravnovešenje, regulacija sistema, toplotno ugodje
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[J. Bahovec]
Year:2020
Number of pages:XXII, 60 str., [5] zganj. pril.
PID:20.500.12556/RUL-118197 This link opens in a new window
UDC:697:628.8:696(043.2)
COBISS.SI-ID:28013571 This link opens in a new window
Publication date in RUL:26.08.2020
Views:1038
Downloads:160
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Revision of project documentation of mechanical installations and comparison with alternative solutions
Abstract:
In the master's thesis, we performed a revision of the originally obtained project documentation of the mechanical installations for the office building and compared it with alternative solutions. The project documentation for the business facility was examined, critically assessed and appropriate optimal corrections were made. Appropriate adjustments have been made to ensure hydraulic balancing, indoor environment quality, air quality and optimal energy consumption for heating, cooling and ventilation. With the corrections, we improved the operation of the system, the well-being of staff in the workplace and reduced electricity consumption.

Keywords:heating, cooling, air conditioning, hydraulic balancing, system regulation, thermal comfort