Details

Radiation hardness of CMOS detector prototypes for ATLAS Phase II ITk upgrade
ID Hiti, Bojan (Author), ID Mandić, Igor (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (17,62 MB)
MD5: 66B7056A67313C5625BDF5E0716FFE30

Abstract
This thesis presents a study of charge collection properties and its dependence on displacement damage caused by irradiation in CMOS detector prototypes developed for the phase-II upgrade of the Inner Tracker (ITk) in ATLAS experiment. Investigated samples were developed in four separate development lines and manufactured in different industrial processes. The main design parameters studied in this work are initial resistivity and the size of collection electrode. Samples were irradiated with reactor neutrons to fluences between 1013 neq/cm2 and 1016 neq/cm2 and with protons to fluences between 1014 neq/cm2 and 3.6 ˙ 1015 neq/cm2. Charge collection in the samples was characterised with Edge-TCT, radioactive 90Sr beta source and in a highly energetic pion test beam. Measurements of effective space charge concentration with Edge-TCT show significant radiation dependence influenced by initial acceptor removal. Acceptor removal is slower at lower initial substrate resistivity and is typically finished at a fluence of 1013 neq/cm2 in highly resistive 2 kΩcm material and 1015 neq/cm2 in material with initial resistivity of 20 Ωcm. Acceptor removal may cause the increase of the depth of depletion zone in certain range of fluences which was observed by both Edge-TCT and 90Sr. Measurements of in-pixel hit detection efficiency with test beam revealed significant efficiency gaps on pixel edges in samples with a small collection electrode after irradiation. These results prompted modifications of pixel design in form of additional implanted structures which are expected to significantly improve detector performance.

Language:English
Keywords:ATLAS ITk, CERN, HL-LHC, Silicon detectors, Radiation damage, Charge transport, Acceptor removal, Radiation hard detectors, DMAPS, HV-CMOS, HR-CMOS
Work type:Doctoral dissertation
Typology:2.08 - Doctoral Dissertation
Organization:FMF - Faculty of Mathematics and Physics
Year:2020
PID:20.500.12556/RUL-115344 This link opens in a new window
COBISS.SI-ID:3418724 This link opens in a new window
Publication date in RUL:23.04.2020
Views:1824
Downloads:334
Metadata:XML DC-XML DC-RDF
:
HITI, Bojan, 2020, Radiation hardness of CMOS detector prototypes for ATLAS Phase II ITk upgrade [online]. Doctoral dissertation. [Accessed 6 April 2025]. Retrieved from: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=eng&id=115344
Copy citation
Share:Bookmark and Share

Secondary language

Language:Slovenian
Title:Sevalna odpornost detektorjev CMOS za nadgradnjo notranjega sledilnika ATLAS
Abstract:
V doktorskem delu je predstavljena študija zbiranja naboja v odvisnosti od sevalnih poškodb v detektorjih CMOS zasnovanih za nadgradnjo (Phase-II) Notranjega sledilnika ATLAS ITk. Preučevani vzorci so bili razviti v štirih vzporednih razvojnih smereh in izdelani v različnih industrijskih procesih. Glavna dejavnika preučevana v tem delu sta začetna upornost senzorja in velikost zbiralne elektrode. Vzorci so bili obsevani z reaktorskimi nevtroni v območju fluenc 1013 neq/cm21016 neq/cm2 in s protoni od 1014 neq/cm23.6 ˙ 1015 neq/cm2. Zbiranje naboja v vzorcih je bilo opredeljeno z meritvami z metodo e-TCT, radioaktivnim virom β 90Sr in v visokoenergijskem testnem žarku pionov. Meritve efektivne koncentracije prostorskega naboja z metodo e-TCT kažejo na veliko odvisnost od obsevanja, na katero vpliva tudi efektivna odstranitev začetnih akceptorjev. Ta poteka počasneje v materialih z nižjo začetno upornostjo in se tipično konča okoli fluence 1013 neq/cm2 v materialu z visoko začetno upornostjo 2 kΩcm ter okoli fluence 1015 neq/cm2 v materialu z nizko začetno upornostjo 20 Ωcm. Odstranitev akceptorjev lahko povzroči povečanje osiromašenega področja v senzorju v določenem območju fluenc, kar je bilo opaženo v meritvah z metodo e-TCT in z radioaktivnim virom 90Sr. Meritve v detektorju z majhno zbiralno elektrodo s testnim žarkom so razkrile območja z nizko učinkovitostjo znotraj blazinice po obsevanju. Na podlagi teh rezultatov so bile uvedene spremembe zasnove blazinic, ki bodo po pričakovanjih izboljšale zbiranje naboja v tem detektorju.

Keywords:ATLAS ITk, CERN, HL-LHC, Silicijevi detektorji, Detektorji odporni na sevanje, Sevalne poškodbe, Transport nosilcev naboja, Odstranitev akceptorjev, DMAPS, HV-CMOS, HR-CMOS

Similar documents

Similar works from RUL:
  1. Meritve sevalnih poškodb v silicijevih detektorjih
  2. Measurements of timing properties of a CMOS charged particle detector
  3. Aerogel ring imaging Cherenkov detector with silicon photomultipliers
  4. Studies of inter-pad distance in Low-Gain Avalanche Detectors
  5. Zaznavanje nabitih delcev s pasovnimi silicijevimi detektorji pri preletu pod velikimi koti
Similar works from other Slovenian collections:
  1. Meritve vpliva zaporne napetosti na napetost popolnega osiromašenja v silicijevih detektorjih

Back