izpis_h1_title_alt

Karakterizacija sklepov biodinamskega sistema prsta na roki
ID Rogelj, Jakob (Author), ID Čepon, Gregor (Mentor) More about this mentor... This link opens in a new window, ID Boltežar, Miha (Comentor)

.pdfPDF - Presentation file, Download (6,40 MB)
MD5: FBB5F4C20C0E3C3224C9EB5036AC65F9

Abstract
Magistrsko delo obravnava problematiko vibracijskih bolezni in s tem povezano problematiko karakterizacije biodinamskega sistema, prsta na roki. Natančneje se osredotoči na določitev parametrov togosti povezav numeričnega modela prsta na roki. V delu predstavimo razvit algoritem za določitev optimalne ravnovesne lege sistema v procesu identifikacije togosti spojev. Z uporabo predlaganega pristopa je mogoče lokalizirati vpliv parametrov togosti posameznega sklepa na eno samo lastno frekvenco. Predstavljena numerični in eksperimentalni primer predstavita učinkovitost razvitega algoritma za določitev spojev ter s tem pomembnost pravilne izbire lege sistema tekom izvedbe postopka linearizacije gibalnih enačb.

Language:Slovenian
Keywords:linearizacija, ravnovesna lega, togost spojev, občutljivostna analiza, sistem togih teles, prsti na roki
Work type:Master's thesis/paper
Typology:2.09 - Master's Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[J. Rogelj]
Year:2019
Number of pages:XXIII, 66 str.
PID:20.500.12556/RUL-112606 This link opens in a new window
UDC:531:612.75:517.977.166(043.2)
COBISS.SI-ID:16963099 This link opens in a new window
Publication date in RUL:26.10.2019
Views:1846
Downloads:330
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Dynamic characterization of joints in the finger-hand biodynamic system
Abstract:
The master’s thesis presents the joint-parameter characterization of the finger-hand biodynamic system. The characterization focuses on the joint stiffness identification for numerical model of human finger. Presented novel method introduces the system’s equilibrium-point selection algorithm into the joint-parameter identification process. Using the proposed approach it is possible to localize the influence of the individual joint’s stiffness parameters to one particular natural frequency. The presented case study highlights the efficiency of the developed parameter-estimation procedure and with this the importance of a proper linearization equilibrium-point selection for a reliable and accurate parameter-identification process.

Keywords:linearization, equilibrium point, joint parameters, sensitivity analysis, multibody system, human fingers

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back