Prenova ovoja enodružinske hiše v Podgorju pri Slovenj Gradcu : diplomska naloga
ID
Pirnat, Denis
(
Author
),
ID
Dovjak, Mateja
(
Mentor
)
More about this mentor...
,
ID
Antolinc, David
(
Comentor
)
PDF - Presentation file,
Download
(5,56 MB)
MD5: B85ED73396E6C157E4449F8F41F83AFE
Image galllery
Abstract
Trend gradnje in prenove stavb gre v smer boljše energijske učinkovitosti in zmanjšanja vpliva na okolje. V ta namen se starejšim objektom pri prenovi dodaja toplotno izolacijo, saj je ti običajno nimajo, ali pa je le-te premalo, da bi dosegali željeno toplotno prehodnost. Dodajanje toplotne izolacije je najpogostejši ukrep v praksi, za večjo učinkovitost pa se izvajajo celovite sanacije. Pri sanaciji objektov pa je potrebno zagotoviti tudi kakovostno notranje bivalno okolje. Zgoraj opisano je bil povod za mojo diplomsko nalogo, kjer sem želel sanirati stavbni ovoj enodružinske hiše, ki se nahaja v Podgorju pri Slovenj Gradcu. Za obstoječe konstrukcijske sklope (zunanja stena nad terenom, zunanja stena pod terenom, tla na terenu, medetažna konstrukcija proti podstrešju, stena proti neogrevanemu prostoru, tla proti neogrevanemu prostoru) sem izračunal izbrane gradbeno-fizikalne parametre ter parametre kakovosti notranjega okolja. Ti parametri so: toplotna prehodnost, kondenzacija vodne pare in čas izsuševanja le-te, fazni zamik in faktor dušenja amplitude temperaturnega nihanja zraka v prostoru, notranja površinska temperatura in pripadajoča relativna zračna vlažnost ter toplotna kapaciteta. Za vse izračune sem uporabil programsko orodje U-wert. V drugem delu diplomske naloge sem predlagal rešitve obstoječih konstrukcijskih sklopov in izračunal gradbeno-fizikalne parametre ter parametre kakovosti notranjega okolja še za predlagane rešitve. Vse dobljene rezultate analize sem primerjal z zakonsko zahtevanimi in priporočili.
Language:
Slovenian
Keywords:
enodružinska hiša
,
prenova
,
ovoj
,
gradbeno-fizikalni parametri
,
parametri kakovosti notranjega okolja
Work type:
Bachelor thesis/paper
Typology:
2.11 - Undergraduate Thesis
Organization:
FGG - Faculty of Civil and Geodetic Engineering
Publisher:
D. Pirnat]
Year:
2019
PID:
20.500.12556/RUL-111007
UDC:
699.76:728.3(497.4)(043.2)
COBISS.SI-ID:
8901473
Publication date in RUL:
22.09.2019
Views:
1823
Downloads:
283
Metadata:
Cite this work
Plain text
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
PIRNAT, Denis, 2019,
Prenova ovoja enodružinske hiše v Podgorju pri Slovenj Gradcu : diplomska naloga
[online]. Bachelor’s thesis. D. Pirnat. [Accessed 18 April 2025]. Retrieved from: https://repozitorij.uni-lj.si/IzpisGradiva.php?lang=eng&id=111007
Copy citation
Share:
Secondary language
Language:
English
Title:
Renovating envelope of a detached house located in Podgorje pri Slovenj Gradcu : graduation thesis
Abstract:
The trend of the construction and renovation of buildings goes in the direction of better energy efficiency and reduction of the impact on the environment. Thermal insulation is added to older constructions in order to achieve this, since they typically do not contain it, or there is not enough of it to achieve desired thermal conductance. It is also necessary to ensure quality interior living environment during building restoration process. Described above was the main reason for my thesis, in which I wanted to renovate the building envelope of a single-family house, located in Podgorje near Slovenj Gradec. I calculated the building-physics parameters and parameters of the internal environment quality for existing construction systems (exterior wall, the underfround exterior wall, floor on the ground, the attic floor, wall against cold room, the ground against the cold room). These parameters are: thermal transmittance, condensation of water vapour, time of drying, time lag, decrement factor, the inner surface temperature and its relative humidity and heat capacity. I used a software tool U-wert for those calculations. Solutions to the existing construction systems were suggested and building-physics parameters and indoor environmental quality of the proposed solutions were calculated in the second part of the thesis. All the results were compared with legal requirements and recommendations.
Keywords:
detached house
,
renovation
,
building-physics parameters
,
the parameters of the quality of the internal environment
Similar documents
Similar works from RUL:
Efficiency of double skin facade from the aspects of indoor environmental quality and energy use
Energy renovation of building envelope system towards indoor environmental quality and efficient energy use
Analysis of indoor environmntal quality in children day care center with further suggestions for improvment
ǂThe ǂrenovation of the Faculty of Mechanical Engineering, University of Ljubljana in order to achieve optimal indoor environmental quality and minimal building energy use
In-situ measurements of energy indicators and indoor environmental quality indicators in case of a passive house
Similar works from other Slovenian collections:
No similar works found
Back