Abstract
Za merjenje zvezno spreminjajočega tlaka pogosto uporabljamo piezoelektrična zaznavala, povezana s cevko. Prostornina znotraj pokrovčka tlačnega zaznavala lahko odločilno vpliva na dinamične lastnosti merilnega sistema, v katerem se tlačni signal, ki ga izmerimo, razlikuje od merjenega tlaka. V tej nalogi smo ugotavljali lastnosti teh sistemov z različnimi pokrovčki ter cevkami, s katerimi smo obravnavali podkritično in nadkritično dušene sisteme. Izvajali smo meritve na dinamičnem generatorju tlaka z dvema piezoelektričnima zaznavaloma, kjer je bilo eno neposredno pritrjeno na generator za referenco in drugo povezano s cevko. Poleg tega pa smo izračunali karakteristike sistema še s teoretičnimi modeli. Meritve in teoretični modeli so se najbolj ujemali v sistemih s krajšimi cevkami, prostornina je na dušilne razmernike imela večji vpliv pri sistemih s cevkami z majhnim premerom ali krajšo dolžino.
Language:
Slovenian
Keywords:
meritve tlakov
,
vplivi volumnov
,
frekvenčne karakteristike
,
naravne frekvence
,
dušilni razmerniki
,
časovne konstante
Work type:
Final paper
Typology:
2.11 - Undergraduate Thesis
Organization:
FS - Faculty of Mechanical Engineering
Place of publishing:
Ljubljana
Publisher:
[T. Perme]
Year:
2019
Number of pages:
XIV, 23 f.
PID:
20.500.12556/RUL-110493
UDC:
531.787:681.2.08(043.2)
COBISS.SI-ID:
16943643
Publication date in RUL:
15.09.2019
Views:
1382
Downloads:
181
Metadata:
Cite this work
Plain text
BibTeX
EndNote XML
EndNote/Refer
RIS
ABNT
ACM Ref
AMA
APA
Chicago 17th Author-Date
Harvard
IEEE
ISO 690
MLA
Vancouver
:
Copy citation
Share:
Secondary language
Language:
English
Title:
Effects of the internal volume of a pressure sensor on the dynamic properties of a pressure measurement system
Abstract:
Piezoelectric sensors with a connecting tube are often used for measurements of time varying pressure. The volume inside of the sensor cap can have a decisive effect on the properties of measurement system in which the pressure signal within the measured object differs from the measured one. Within this paper we have studied the properties of the systems with different sensor caps and connecting tubes in order to investigate the properties of both underdamped and overdamped systems. The measurements were made on a dynamic pressure generator with two piezoelectric sensors one of which was directly mounted on the generator as a reference and the other connected with a tube. Calculations based on theoretical models were also made. Theoretical models predicted the measured values well for shorter tubes and the internal volume of the cap had a larger effect on damping ratios when shorter tubes or tubes with smaller internal diameter were used.
Keywords:
pressure measurements
,
internal volumes
,
frequency characteristics
,
damping ratios
,
time constants