izpis_h1_title_alt

IONSKA KROMATOGRAFIJA ZA DOLOČEVANJE ANIONOV
ID Tomšič, Rok (Author), ID Kolar, Mitja (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (3,17 MB)
MD5: 8DEED8582A605A14005669FA2BC5206A

Abstract
V okviru diplomskega dela na Fakulteti za kemijo in kemijsko tehnologijo, Univerze v Ljubljani, je bil vpeljan sistem za anionsko izmenjevalno kromatografijo s konduktometrično detekcijo. S sistemom so bile izvedene analize realnih vzorcev v katerih smo določali: fluoridne, kloridne, nitritne, bromidne, nitratne, fosfatne in sulfatne ione. Metoda ionske kromatografije je bila tudi delno validirana, saj smo študirali linearnost ter določili LOD in LOQ. Določali smo primernost oz. vpliv kromatografskih pogojev kot so: pretok in sestava, pH ter starost eluenta. Eksperimentalno delo je vključevalo tudi regeneracijo kolone, s katero smo želeli doseči manjšo asimetričnost vrhov, ustrezno ločitev vrhov, ki pripadata fosfatnim in sulfatnim ionom ter odpraviti zamike retencijskih časov.

Language:Slovenian
Keywords:ionska kromatografija, anioni, validacija, regeneracija kolone
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Technology
Year:2019
PID:20.500.12556/RUL-109665 This link opens in a new window
COBISS.SI-ID:1538327747 This link opens in a new window
Publication date in RUL:06.09.2019
Views:3750
Downloads:685
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Abstract:
As a part of the diploma thesis at the Faculty of Chemistry and Chemical Technology of the University of Ljubljana, an anion exchange chromatography system with conductometric detection was introduced. The system performed analyses of real samples in which we determined: fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulphate ions. The ion chromatography method was also partially validated, as we studied linearity and determined LOD and LOQ. We determined the suitability or the influence of the chromatographic conditions such as: flow and composition, pH and age of the eluent. The experimental work also included the regeneration of the column, which was aimed at reducing the peak asymmetry of the peaks, the proper separation of the peaks belonging to the phosphate and sulphate ions, and to eliminate the retention time delays.

Keywords:ion chromatography, anions, validation, column regeneration