izpis_h1_title_alt

Študija uporabe kompaktnih potenciometričnih senzorjev
ID Imperl, Jernej (Author), ID Kolar, Mitja (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (2,28 MB)
MD5: 6422A94FDE1072D2AC7CFC9B911D1ED2

Abstract
Diplomsko delo zajema študijo lastnosti kompaktnih potenciometričnih senzorjev – pH metrov (Hanna Instruments, Checker – pH tester HI98103) – in njihove možne rabe kot nadomestek stacionarni laboratorijski različici. Opravljena je bila vrsta poskusov. Določen je bil časovni odziv pH metrov z uporabo kalibracijskih pufrov. Preverjena je bila časovna stabilnost kalibracije skozi desetdnevno obdobje z meritvami kalibracijskih pufrov. Preverjena je bila linearnost odziva po pH lestvici z uporabo vrste pufrov od pH 1 do pH 13. Raziskan je bil pojav bazične (natrijeve) napake s pufri pri dveh različnih pH in različno vsebnostjo natrijevih ionov. Preverjena je bila temperaturna odvisnost odziva v delovnem območju pH metra s kalibracijskimi pufri. Preizkušena je bila uporaba pH metrov za spremljanje poteka in določitev končne točke titracij – močna kislina z močno bazo, šibka kislina z močno bazo in večprotonska kislina z močno bazo. Ugotovljeno je bilo, da je časovni odziv odvisen od velikosti spremembe pH in se daljša z večanjem spremembe. Kalibracija pH metrov je zadostno stabilna skozi celotno časovno obdobje in odstopanje v meritvah ne preseže deklarirane napake. Odziv pH metrov je linearen v pH območju 1 – 13. Pri visokih vrednostih pH pH metri izkazujejo natrijevo napako. Temperaturno najbolj občutljive so meritve pri nižjih pH, medtem ko je ta vpliv pri višjih pH zanemarljiv. pH metri so s pravim postopkom uporabni za vse preizkušene titracije in omogočajo spremljanje poteka in določitev končne točke titracije. Kompaktni pH metri (Hanna Instruments, Checker – pH tester HI98103) so zaradi priročne oblike in enostavnega delovanja primerni za terensko delo. V laboratorijskem okolju so lahko rabljeni pri študijskih laboratorijskih vajah, za direktno potenicometrijo ali potenciometrično titracijo in manj natančno delo v analizi.

Language:Slovenian
Keywords:kompaktni potenciometrični senzor, pH meter, pH, direktna potenciometrija, potenciometrična titracija
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FKKT - Faculty of Chemistry and Chemical Technology
Year:2019
PID:20.500.12556/RUL-109508 This link opens in a new window
COBISS.SI-ID:1538511043 This link opens in a new window
Publication date in RUL:04.09.2019
Views:1570
Downloads:298
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:A Study of Compact Potentiometric Sensors
Abstract:
The following dissertation is a study of the properties of compact potentiometric sensors – pH meters (Hanna Instruments, Checker – pH tester HI98103) – and their possible usage as a substitute for a stationary laboratory pH meter. A series of experiments was carried out. Time needed for a pH meter to reach a steady response was determined using calibration buffers. Time stability of calibration was observed for a ten-day period with measurements of calibration buffers. The linearity of the pH meter response was tested with the use of buffers with pH 1 through 13. The occurrence of alkaline error was investigated with buffers with different pH and different sodium ion concentrations. The application of pH meter for titrations and the determination of end points was examined with various types of titration; a strong acid with a strong base, a weak acid with a strong base and a polyprotic acid with a strong base. It was determined that the time needed for a pH meter to reach a steady response is dependent on the size of the difference of pH values and correspondingly lengthens with a larger difference in pH. The calibration of pH meter is sufficiently stable in the experimental time period and the measurement deviation does not exceed the value of the inherent error of the pH meter. The response of the pH meter is linear in the whole pH range (from pH 1 to pH 13). The alkaline error was observed at high pH values. Measured pH values at lower pH are very temperature dependent, as opposed to measured pH values at higher pH, where the variance is negligible. pH meter is applicable for all types of titration and the determination of the end point. Compact pH meter (Hanna Instruments, Checker – pH tester HI98103) is a hand-held device, that can be simply operated and is thus appropriate for field work. In a laboratory environment the pH meter is usable for student laboratory practice, for direct potentiometry and potentiometric titrations and less accurate analyses.

Keywords:compact potentiometric sensor, pH meter, pH, direct potentiometry, potentiometric titration

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back