Abstract
Razvoj industrije je prinesel vse večje povpraševanje po merjenju in zaznavanju površin s 3D-merilniki. Ena izmed modernih in vse bolj pogosto uporabljenih tehnik je metoda merjenja površine s projiciranjem fazno zamaknjenih sinusnih vzorcev, ki jih zajemamo s kamero. Odlikuje jo hitrost in natančnost zajemanja 3D-oblike površine. Za izboljšanje rezultatov je potrebno izvesti kalibracijo celotnega merilnega sistema. Kalibracija kamere je dobro raziskan in uveljavljen postopek, ki dosega odlične rezultate. Kalibracijo projektorja raziskovalci obravnavajo kot inverzno kamero, kar zaradi zamika optične linije ali netelecentričnosti projektorja privede do netočnosti kalibracije. Za doseganje večje natančnosti kalibracije večina člankov obravnava kamero in projektor kot skupen sistem, ki pri različnih metodah kalibracije privede do bolj ali manj natančnih rezultatov. Pristopi h kalibriranju opisane metode se delijo na tabelarični pristop korigiranja vsake točke posebej in parametrični pristop korigiranja točk s funkcijskim popisom tangencialne in radialne distorzije. Pristopa se poleg metode razlikujeta tudi v natančnosti rezultatov, trajanju obdelave podatkov in po morebitnih dodatnih elementih v merilnem sistemu.

Language:Slovenian
Keywords:kalibracija, distorzija, projektorji, kamere, 3D merilniki, parametrične korekcije, tabelarični pristop korekciji
Work type:Final paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[L. Brglez]
Year:2019
Number of pages:XIII, 28 f.
PID:20.500.12556/RUL-109244 This link opens in a new window
UDC:681.77:004.925.84(043.2)
COBISS.SI-ID:16779291 This link opens in a new window
Publication date in RUL:29.08.2019
Views:1404
Downloads:189
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Projector distortion calibration in triangulation measurement system
Abstract:
Industrial development has brought increasing demand for 3D measurement systems. One of the modern and commonly used techniques consists of fringe projections cast by projector and captured by camera. It is distinguished by its speed and accuracy of capturing 3D images. In order to improve its results it is necessary to perform calibration of the entire measurement system. Camera calibration is well-researched and explained process achieving excellent results. Projector calibration is regarded as the calibration of the reverse camera, which is not quite suitable because optical offset of the projector and causes inaccurate calibration. To achieve greater calibration accuracy most articles approach camera and projector as combined system which leads to more or less precise results from different calibration techniques. Calibration approaches are divided in to construction of lookup tables with corrections for each separate pixel and parametric distortion model which uses mathematical models of radial an tangential distortion to correct each pixel. Approaches differ in accuracy, speed and convenience of measurement and results or the type of additional equipment in the measurement system.

Keywords:calibration, distortion, projectors, cameras, 3D measurement systems, parametric distortion corrections, lookup tables distortion correction