izpis_h1_title_alt

Testiranje obtočnih ventilov filtrov
ID Korpič, Sandi (Author), ID Majdič, Franc (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (9,59 MB)
MD5: EA96A665FC0A8EF55AA9335F0AF708F7

Abstract
Obtočni ventili so sestavni del filtrskih vložkov, ki se v večini primerov uporabljajo v hidravličnih napravah. Najpomembnejši parameter obtočnega ventila je odpiralni tlak, ki pa je odvisen od pretoka, kar popiše Δp-Q-karakteristika. V delu smo z dvema medijema, tj. z zrakom in s hidravličnim oljem, določili odpiralne tlake za že razvite obtočne ventile ter ugotavljali, kako uporabljeni medij vpliva na odpiralni tlak. Tlake smo predhodno preprosto analitično ocenili, kasneje pa smo te izračune preverili še z meritvami. Ugotovljeno je bilo, da je primerjava med zrakom in oljem možna, vendar odvisna od oblike obtočnega ventila.

Language:Slovenian
Keywords:obtočni ventili filtrski vložki filtri odpiralni tlak Δ, p-Q-diagrami
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FS - Faculty of Mechanical Engineering
Place of publishing:Ljubljana
Publisher:[S. Korpič]
Year:2018
Number of pages:XXII, 70 str.
PID:20.500.12556/RUL-101506 This link opens in a new window
UDC:519.6:62-3(043.2)
COBISS.SI-ID:16105243 This link opens in a new window
Publication date in RUL:13.06.2018
Views:1293
Downloads:241
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Testing the filter by-pass valves
Abstract:
Filter by-pass valves are an essential part of filter cartridges, which, in most cases, are used in hydraulic assemblies. The main parameter of a by-pass valve is the opening pressure, which depends on the flow through the valve. The both parameters together are written in the Δp-Q-characteristic of the valve. In this thesis we were determining the opening pressures for already constructed valves, with two different media - air and hydraulic oil. The goal was to correlate how the media influences the opening pressure. The values were first analytically checked and also measured in real life scenario after. We could establish that a correlation between air and oil used is possible, but highly dependable on the shape of the by-pass valve itself.

Keywords:pressure control valves filter cartridges filters openning pressure Δ, p-Q-diagrams