izpis_h1_title_alt

Dynamics of cell death due to electroporation using different pulse parameters as revealed by diferent viability assays
ID Peng, Wencheng (Avtor), ID Polajžer, Tamara (Avtor), ID Yao, Chenguo (Avtor), ID Miklavčič, Damijan (Avtor)

.pdfPDF - Predstavitvena datoteka, prenos (8,95 MB)
MD5: 5F91A7C1C169A2867117AEC25DFD0A78
URLURL - Izvorni URL, za dostop obiščite https://link.springer.com/article/10.1007/s10439-023-03309-8 Povezava se odpre v novem oknu

Izvleček
The mechanisms of cell death due to electroporation are still not well understood. Recent studies suggest that cell death due to electroporation is not an immediate all-or-nothing response but rather a dynamic process that occurs over a prolonged period of time. To investigate whether the dynamics of cell death depends on the pulse parameters or cell lines, we exposed different cell lines to different pulses [monopolar millisecond, microsecond, nanosecond, and high-frequency bipolar (HFIRE)] and then assessed viability at different times using different viability assays. The dynamics of cell death was observed by changes in metabolic activity and membrane integrity. In addition, regardless of pulse or cell line, the dynamics of cell death was observed only at high electroporation intensities, i.e., high pulse amplitudes and/or pulse number. Considering the dynamics of cell death, the clonogenic assay should remain the preferred viability assay for assessing viability after electroporation.

Jezik:Angleški jezik
Ključne besede:electroporation, pulsed field ablation, cell death dynamics, pulse parameters, viability assays
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FE - Fakulteta za elektrotehniko
Status publikacije:Objavljeno
Različica publikacije:Objavljena publikacija
Leto izida:2024
Št. strani:Str. 22-35
Številčenje:Vol. 52, iss. 1
PID:20.500.12556/RUL-154040 Povezava se odpre v novem oknu
UDK:602.621
ISSN pri članku:0090-6964
DOI:10.1007/s10439-023-03309-8 Povezava se odpre v novem oknu
COBISS.SI-ID:164795907 Povezava se odpre v novem oknu
Datum objave v RUL:22.01.2024
Število ogledov:350
Število prenosov:19
Metapodatki:XML RDF-CHPDL DC-XML DC-RDF
:
Kopiraj citat
Objavi na:Bookmark and Share

Gradivo je del revije

Naslov:Annals of biomedical engineering
Skrajšan naslov:Ann. biomed. eng.
Založnik:Springer Nature, Biomedical Engineering Society
ISSN:0090-6964
COBISS.SI-ID:560916 Povezava se odpre v novem oknu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:elektroporacija, ablacija s pulznim električnim poljem, dinamika celične smrti, parametri pulza, testi preživetja

Projekti

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:P2-0249
Naslov:Elektroporacija v biologiji, biotehnologiji in medicini

Financer:Drugi - Drug financer ali več financerjev
Program financ.:Medtronic, Inc.

Financer:Drugi - Drug financer ali več financerjev
Program financ.:China Scholarship Council

Financer:ARRS - Agencija za raziskovalno dejavnost Republike Slovenije
Številka projekta:I0-0022
Naslov:Mreža raziskovalnih infrastrukturnih centrov Univerze v Ljubljani (MRIC UL)

Podobna dela

Podobna dela v RUL:
Podobna dela v drugih slovenskih zbirkah:

Nazaj