In this work, harmful products that are produced during the FDM printing are identified, namely ultrafine particles and hazardous volatile organic compounds. Based on that, a filtering system is defined comprised of HEPA filters used to filter out ultrafine particles and filters with active carbon to filter out hazardous volatile organic compounds. A chamber for the printer is constructed that has implemented both filters and ventilator. Additionally, it acoustically isolates the printer from the environment and it enables easy access to the printer.
|