V diplomski nalogi bomo preverjali ustreznost optičnega merilnega sistema v primerjavi z merilnim koordinatnim strojem, profilomerom ter merilno kamero. Na vsakem od zgoraj naštetih strojev bomo izvedli določeno število meritev ter nato ugotavljali ustreznost optičnega merilnega sistema. Ugotavljanje ustreznosti optičnega merilnega sistema bo potekalo na neobdelanem ulitku iz aluminija. Za vsak stroj posebej bomo izračunali raztros posameznega stroja, največjo razliko med maksimalno in minimalno vrednostjo ter raztros oziroma ponovljivost samega stroja.

Language:Slovenian
Keywords:Merilna negotovost, merilna točnost in natančnost, raztros, ponovljivost, koordinatni merilni stroj, optični merilni stroj, profilomer, merilna kamera.
Work type:Bachelor thesis/paper
Organization:FS - Faculty of Mechanical Engineering
Year:2017
PID:20.500.12556/RUL-92966 This link opens in a new window
Publication date in RUL:11.07.2017
Views:1977
Downloads:270
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Feasibility analysis of dimensional control of castings with the optical measuring system
Abstract:
In this thesis we will verify the adequacy of the optical measuring system in comparison with the coordinate measuring machine, contour measuring machine and measuring camera. In each of the above mentioned machines we will perform a certain number of measurements and then we will find out if the optical measuring system is suitable for use. All measurements will be performed on a rough aluminium casting. For each machine separately the scatter / dispersion and the highest difference between the maximum and minimum value will be calculated.

Keywords:measurement uncertainty, measurement accuracy and precision, scatter / dispersion, repeatability, coordinate measuring machine, optical measuring system, contour measuring, measuring camera