Abstract
V diplomski nalogi je prikazan izračun standardne požarne odpornosti prostoležečih lesenih nosilcev skladno s standardom SIST EN 1995-1-2:2005 – Evrokod 5: Projektiranje lesenih konstrukcij – 1-2. del: Splošna pravila – Projektiranje požarnovarnih konstrukcij. Standard podaja dve poenostavljeni metodi za izračun požarne odpornosti elementov. V nalogi je predstavljena metoda z zmanjšanim prečnim prerezom. Analizirani so stropni nosilci s konstantnim prečnim prerezom iz masivnega in lepljenega lameliranega lesa ter ravni dvokapni strešni nosilec iz lepljenega lameliranega lesa. Poleg računskih kontrol požarne odpornosti so prikazane tudi računske kontrole v mejnem stanju nosilnosti in mejnem stanju uporabnosti v običajnih pogojih, ki so izvedene skladno s standardom SIST EN 1995-1-1:2005 – Evrokod 5: Projektiranje lesenih konstrukcij – 1-1. del: Splošna pravila in pravila za stavbe. Izkaže se, da je požarna odpornost lesenih nosilcev relativno velika (> R60), kar je posledica dejstva, da je za dimenzioniranje nosilcev merodajna kontrola v mejnem stanju uporabnosti.

Language:Slovenian
Keywords:leseni nosilec, lameliran les, požarna odpornost, poenostavljena metoda, Evrokod 5
Work type:Bachelor thesis/paper
Typology:2.11 - Undergraduate Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Publisher:[Živa Pavšič]
Year:2017
PID:20.500.12556/RUL-92523 This link opens in a new window
UDC:614.8:624.011.1(043.2)
COBISS.SI-ID:8082273 This link opens in a new window
Publication date in RUL:06.06.2017
Views:6917
Downloads:597
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Calculation of standard fire resistance of glued laminated timber beams
Abstract:
In this graduation thesis the calculation of standard fire resistance of a simple single span timber beam is presented. The calculation is executed in accordance with EN 1995-1-2:2005 – Eurocode 5: Design of timber structures – Part 1-2: General - Structural fire design. Standard gives two simplified methods for determining fire resistance, the thesis is focused on reduced cross section method. Fire resistance is determined for floor beams with constant cross-section, made from solid timber and from glued laminated timber, and also for glued laminated timber roof beam with variable cross-section. Design of beams for ultimate and serviceability limit state is also executed in accordance with EN 1995-1-1:2005 – Design of timber structures – Part 1-1: General - Common rules and rules for buildings. On the basis of presented study it can be concluded that the fire resistance of timber beams is relatively high (> R60) which is a consequence of serviceability limit state being relevant for the ambient design of the beams.

Keywords:timber beam, glued laminated timber, fire resistance, simplified method, Eurocode 5