izpis_h1_title_alt

Primerjava statičnega in dinamičnega obremenilnega preizkusa testnega pilota v barjanskih tleh : diplomska naloga
ID Erbežnik, Miha (Author), ID Logar, Janko (Mentor) More about this mentor... This link opens in a new window

.pdfPDF - Presentation file, Download (4,85 MB)
MD5: 0FD9DED8F0BDF7B23367E9657B05CAF5
PID: 20.500.12556/rul/76428f53-3544-45a5-b7b4-cc946678327f

Abstract
Gradnja objektov se je v zadnjem desetletju izrazito povečala na območjih slabih temeljnih tal in s tem so se povečale potrebe po gradnji pilotov. Kakovost izvedbe pilotov je potrebno v skladu s standardi preverjati, za kar se uporablja preizkus zveznosti, pri zahtevnejših objektih pa je potrebno preveriti tudi nosilnost z uporabo statičnega ali dinamičnega obremenilnega testa. Izvedba testov in analiza rezultatov se med seboj zelo razlikujeta, a v splošnem velja, da je rezultat statičnega obremenilnega testa bolj zanesljiv, medtem ko je dinamični obremenilni test cenejši in bistveno hitrejši. V diplomski nalogi smo predstavili razlike med obema testoma ter rezultate obeh testov na testnem pilotu, zgrajenem v slabih barjanskih tleh. Ker temeljna tla bistveno vplivajo na nosilnost, smo temeljna tla primerno raziskali in na podlagi dobljenih karakteristik zemljine izračunali računsko nosilnost testnega pilota. V nadaljevanju smo podrobno predstavili oba obremenilna testa, tako izvedbo meritev, kakor tudi analizo le-teh. Rezultate meritev smo podrobno analizirali in jih prikazali s krivuljo v grafu obtežba - pomik. Iz rezultatov smo podali ugotovitve in zaključke o razlikah obeh obremenilnih testov, ugotovljenih na primerjavi rezultatov.

Language:Slovenian
Keywords:gradbeništvo, diplomska dela, UNI, dilatometer, statični obremenilni test, dinamičniobremenilni test, PDA, CAPWAP, mejna nosilnost pilota
Work type:Undergraduate thesis
Typology:2.11 - Undergraduate Thesis
Organization:FGG - Faculty of Civil and Geodetic Engineering
Place of publishing:Ljubljana
Publisher:[M. Erbežnik]
Year:2012
Number of pages:XI f., 102 str.
PID:20.500.12556/RUL-32629 This link opens in a new window
UDC:624.131(043.2)
COBISS.SI-ID:5793889 This link opens in a new window
Publication date in RUL:10.07.2015
Views:3953
Downloads:653
Metadata:XML DC-XML DC-RDF
:
Copy citation
Share:Bookmark and Share

Secondary language

Language:English
Title:Comparison between static and dynamic pile load test in marsh soil
Abstract:
Construction of buildings has increased markedly over the past decades in areas of poor foundation soil, which led to increased need for construction of piles. In accordance with European standards, quality control of installed piles has to be done. Quickest and simplest test is low strain intergity test, but in cases of complex structures a static or dynamic pile load test must be made. Execution of tests and analysis of the results are very different, but the final results are the same. In general it is known that the static load test is more reliable, but the dynamic load test is more cost efficient and quicker. In the thesis we present the differences between these tests, and the results of both tests on a test pile built in marsh ground. Due to the fact, that the soil has a significant impact on ultimate pile bearing capacity, we properly invastigated the soil, and from the results calculated the pile ultimate bearing capacity. In the following chapters we present in detail both tests. Measurement results are analyzed and shown by a load - settlement curve. From the results we present findings and conclusions about the difference found during the experiment.

Keywords:graduation thesis, civil engineering, dilatometer, static pile load test, dynamic pile load test, PDA, CAPWAP

Similar documents

Similar works from RUL:
Similar works from other Slovenian collections:

Back